27
CAUTION
* Do not start the engine when the machine and the load circuit breaker are "ON"
position, or else, power is supplied to the load at the start of the engine, which causes
electric shocks or trouble in the load.
Startup
procedure
Turn the fuel filter cock to open before starting engine.
(1) Make sure that the circuit breakers of the machine and the
loads are all "OFF" position.
(2) Set the throttle handle in the "START/IDLING" position.
(3) Turn the starter switch to "PREHEAT" position, then
preheat lamp goes on. This position is held until the
preheat lamp goes off, then preheat is completion.
Turn the starter switch to "START" position until engine
starts.
[Note]
:
If the engine is warm, the preheat operation is not required.
(4) If engine starts up, set free the starter switch.
Make sure that
「
Oil Pressure Failure
」
and
「
Insufficient
charge
」
in the warning lamp unit goes off.
(5) Drive the machine for warming up the engine for about 5
minutes at the "START/IDLING" position of the throttle
lever.
(6) After warming up the engine, set the throttle lever to the
"RUN" position. And check on the idling speed is as
specified in the following table by the frequency meter.
If the idling speed is not as specified or change of
frequency is required, adjust the idling speed by the
frequency adjust screw.
Frequency (No Load Position)
Operation at 50Hz
52.5Hz (1575min
-1
)
Operation at 60Hz
62.5Hz (1875min
-1
)
If the idling speed set above speed, frequency becomes
nearly 50Hz or 60Hz in the rated load.
(7) Set the voltage to the rated by the voltage regulator,
and turn the breaker to "ON". The machine starts power
transmission state.