background image

29

www.DentalEZ.com

 866-DTE-INFO

29

DentalEZ

®

 

Equipment

PN: 2717-256E

Section V  Care

Disinfecting

Upholstery

The NuSimplicity Chair’s upholstery is comprised 

of material from the following manufacturers:

MorCare

TM

 Collection from Morbern

MorGuard from Morbern was developed to 

meet the increased demands of hospital, 

contract and institutional use. MorGuard o

ff

 ers 

enhanced resistance to most common chemicals 

used for sterilization and cleaning in medical 

environments. MorGuard contains both an 

antibacterial and antimicrobial agents to provide 

resistance to a wide range of bacteria.

Naugahyde® Beauty Gard® from Uniroyal

Naugahyde brand fabrics, Spirit II and 

Neochrome II with Advanced Beauty Gard 

contains an agent to protect it against bacterial 

and fungal microorganisms. This product has 

been formulated to achieve a superior level 

of disinfectability with disinfectant products 

containing sodium hypochlorite (common 

household bleach) diluted 1:10.

Mayer/Savoy with 

PERMA

BLOK3

®

 from Spradling®

Mayer/Savoy fabrics with 

PERMA

BLOK3

 advanced 

vinyl protection contain an antimicrobial and 

antibacterial protection on an anti-stain 

fi

 nish that 

is easily cleaned. Mayer/Savoy with 

PERMA

BLOK3

 

provides exceptional disinfectability using a wide 

range of cleaning products.

Ultraleather® from Ultrafabrics®

•  Disinfect with a 5:1 non-chlorinated bleach 

solution.

•  Potentially toxic aftercare not required.

MorCare is a trademark of Morbern, USA Inc.

Naugahyde and Beauty Gard are a registered trademarks of 

Uniroyal Engineered Products, Inc. 

PERMABLOK3 is a registered trademark of Spradling International, 

Inc.

All Other Chair Surfaces

Cavicide

TM

 from Metrex

TM

 Research

Cavicide is recommended for disinfecting all other 

surfaces of the NuSimplicity Chair. The use of 

any disinfectant other than Cavicide may cause 

premature staining, discoloration or damage to the 

NuSimplicity Chair’s materials.

Cavicide is a trademark of Metrex Research, LLC.

Summary of Contents for NuSimplicity

Page 1: ...NuSimplicityTM Chair User Manual ...

Page 2: ...ols 13 Air Glide Optional 15 Upholstery 16 Installation Checklist 18 Section IV Operation Base Lowering Safety Switch 19 Chair Rotation 19 Armrests 20 Standard Fixed Headrest 20 Double Articulating Headrest Optional 21 Air Glide Optional 21 Manual Chair Positioning 22 Automatic Chair Positioning 23 Programming Chair Travel Limits 24 Control Valve Speed Adjustment 25 Section V Care Cleaning 27 Disi...

Page 3: ...www DentalEZ com 866 DTE INFO ii NuSimplicityTM Chair PN 2717 256E ...

Page 4: ...hair Headrest Back Seat Armrest Brake Base Cantilever Section Base Pump Cover Armrest Base Plate Touchpad Foot Control Wired or Wireless This manual contains the installation operation and care instructions and user service information for the DentalEZ NuSimplicity Chair The NuSimplicity Chair is intended to be used by trained professional dental care personnel only The dental chair supports a pat...

Page 5: ...top of chair back Easily visible illuminated ON indicator Slim wider cantilever for ease of internal umbilical Integrated touchpad controls located on both sides of upper backrest provide easy and rapid patient positioning Simple chair controls include auto return last position three presets and manual settings Seamless or seamed upholstery Fixed headrest Base safety switch feature ensures nothing...

Page 6: ...E INFO 3 DentalEZ Equipment PN 2717 256E Section I Introduction Dimensions Figure 2 Top view side reclining and side upright dimensions for the NuSimplicity dental chair 26 30 36 56 64 42 13 17 17 19 12 72 18 8 26 9 18 22 25 27 ...

Page 7: ...www DentalEZ com 866 DTE INFO 4 NuSimplicityTM Chair PN 2717 256E Section I Introduction Range of Motion Figure 3 Range of motion for the NuSimplicity dental chair 30 30 ...

Page 8: ...72 kg Maximum Patient Weight Factory tested to lift a load of 300 lb 136 kg Shipping Package Dimensions 58 5 L 34 H 32 5 W Specifications Minimum Installation Space 10 10 3 m 3 m Base Plate Footprint 42 25 106 cm 64 cm Recommended Environmental Conditions TransportationandStorage Temperature range 20 F to 165 F 29 C to 74 C Relative humidity range 0 to 95 Operation Temperature range 41 F to 104 F ...

Page 9: ...chanical hazards only in accordance with UL 60601 1 CAN CSA C22 2 NO 601 1 CAN CSA C22 2 NO 60601 1 08 ANSI AAMI ES60601 1 2005 53HN RISK CLASS 2G The authorized European representative is Dental Hygienics Decontamination DHD 41 Blackwell Drive Braintree Business Park Braintree Essex CM7 2PU UK Phone 44 01787 877877 ext 200 Caution Warning Biohazard Warning Dangerous Voltage General Mandatory Acti...

Page 10: ...acle NOTICE Before proceeding with electrical installation all wiring must be in accordance with NEC and local electrical codes To avoid the risk of electrical shock this equipment must only be connected to a supply mains with protective earth Do not modify the NuSimplicity Chair without permission from DentalEZ The use of ACCESSORY equipment not complying with the equivalent safety requirements o...

Page 11: ...vice pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications however there is no guarantee that interference wi...

Page 12: ... chair must be at its lowest height and all attachments must be secured in their lowest and most central positions possible Failure to comply may result in injury and or damage to equipment The NuSimplicity Chair is shipped with a retaining strap to secure the base mechanism DO NOT REMOVE this strap until the chair is out of the carton and in its position on the floor The chair is heavy and weighs...

Page 13: ...holstery packaging NOTE The base cover must be removed before anchoring the chair Figure 5 NuSimplicity Chair anchor holes Anchor hole Anchor hole Unpacking Upholstery Carton If the upholstery is ordered separately from the chair remove and set aside the following items from the NuSimplicity Chair upholstery assembly packaging Figure 4 Upholstered back assembly Sling assemblies Upholstered seat Up...

Page 14: ...eat frame tube 3 Using a Phillips head screwdriver and two 10 32 pan head screws one in front and one in the rear install a spring cover 4 Secure using four spring cover bracket screws two on top and two underneath 5 Repeat steps 2 through 4 for the opposite spring cover 10 32 Pan Head Screw Rear Spring Cover Bracket Screws Seat Frame Tube Spring Cover Bracket Spring Cover Phillips head screwdrive...

Page 15: ...liary Wiring Harness Figure 7 Auxiliary wiring harness Delivery Units Install console mounted delivery units and Magellan style delivery units according to the manufacturer s instructions supplied with the delivery unit Section III Installation For more information regarding the installation of the additional controller follow the instructions supplied with the touchpad control package A wireless ...

Page 16: ...ntrol and or wireless touchpad control options were ordered they must be paired with the NuSimplicity Chair Tools Required Phillips head Screwdriver Pair Wireless Devices to Chair 1 Raise chair base up its full UP position 2 Remove two 2 Phillips head screws from front of base pump cover and loosen two 2 screws in back of cover then slide off cover Figure 9 3 Make sure wireless device foot control...

Page 17: ...ng correctly 9 Replace base pump cover Unpair Wireless Devices from Chair 1 Raise chair base up its full UP position 2 Hold the remote switch S3 on main chair power control board for 30 seconds Chair will stop beeping and wireless connections will be cleared 3 Re pair other devices as needed Wireless Control Operation After wireless control has been idle for an extended period of time foot control...

Page 18: ...he air pressure by adjusting the air regulator on the base chassis until the chair begins to bounce This is an indication that the air pillow is over pressurized and can not seal to the floor Slowly decrease the pressure until the chair stops bouncing 4 Actuate the air regulator toggle switch Figure 16 at the rear of the chair on the base cantilever section cover Air Regulator Air Glide Tubing Fig...

Page 19: ...hair Figure 18 and install the 1 4 20 thumb screw Slide Bosses Figure 17 Slide bosses Substrate 1 4 20 Thumb Screw Figure 18 Seat frame tube aligned to substrate Back Factory Installed NOTE Make sure the blind grip fasteners are firmly secured to the back of the upholstered chair back 1 Align the two upper and two lower blind grip fasteners on the upholstered chair back to the studs on the chair b...

Page 20: ...ndard Fixed Headrest Blade Figure 20 Standard fixed headrest Blade Double Articulating Headrest Optional Chair Back Casting Opening Figure 21 Double articulating headrest optional 2 Place the magnetic headrest cushion on the chair or the fixed headrest of the chair Magnetic Cushion Figure 22 Headrest shown with magnetic cushion The headrest shown Figure 22 contains magnets which can interfere with...

Page 21: ...on a few times to ensure proper function Does the rotational brake function properly Does the headrest stay in position after adjustment Is the foot switch or touchpad functioning correctly Do all chair functions operate smoothly and quietly Do the armrests lock into position Answering NO to any of these questions is the result of improper installation or a product malfunction After ensuring all c...

Page 22: ... base will start moving upward immediately while the chair emits a constant short warning beep 3 Moving the base up and off of the obstruction deactivates the safety switches and silences the warning beep If any auto position buttons are pressed the chair will sound three short beeps to indicate auto positioning is not available The NuSimplicity Chair is capable of swiveling 30 to either side of i...

Page 23: ... lock it into position Figure 24 NuSimplicity Chair armrest To position the standard fixed headrest Firmly push down or pull up the blade from the chair back to change the standard fixed headrest height Figure 25 NOTE The use of disposable headrest covers is recommended to prevent soiling of the headrest These covers may be purchased through a local dental supplier Standard Fixed Headrest Blade Fi...

Page 24: ...supplier Release Mechanism Double Articulating Headrest Figure 26 Double articulating headrest The optional air glide aids the operator in repositioning the chair To operate the air glide option 1 Make sure the chair is on a smooth hard level and non obstructive surface 2 Activate the air regulator toggle switch on the base cover at the rear section of the chair Figure 27 3 The rear of the chair b...

Page 25: ...igure 28 To operate these controls 1 Select the direction of travel base up base down back up or back down 2 Depress and hold the corresponding button to move chair to factory set travel limit NOTE The chair will continue running until the directional button is released Back Up Button Figure 28 NuSimplicity Chair touchpad control and foot control Base Down Auto Buttons 1 2 and 3 Back Down Button B...

Page 26: ...exit position Last position mode The chair returns to the last position after one mechanical movement Automatic Chair Positioning Activating Auto Positions 1 Depress the 1 2 3 A or L button once on the touchpad control side of chair back foot control or the unit touch pad control 2 A beep will sound 3 The chair will automatically stop in the programmed position selected NOTE Pressing any button on...

Page 27: ...limits have been set correctly Lower Limits 1 Press 2 and 3 on the chair mounted touchpad for five 5 seconds The chair will start to beep and the display will show LL lower limit 2 Lower the base and back to its lowest position limit switches will be engaged 3 Raise the chair base and back to the lowest desired height Ensure that the limit switches are not engaged 4 Press 1 on the chair mounted to...

Page 28: ...he chair a Move the base up and down adjusting the flow controls until it takes 12 seconds for the base tomoveeitherupordownthefulltravel b Move the back up and down adjusting the flow controls until it takes 12 seconds for the back tomoveeitherupordownthefulltravel NOTE With the flow adjustments closed all the way the seat may not move at all until the valve is adjusted open a little CV1 CV2 UP D...

Page 29: ...www DentalEZ com 866 DTE INFO 26 NuSimplicityTM Chair PN 2717 256E ...

Page 30: ...e harmful or irritating Use protective gloves and eye protection in a well ventilated area Do not inhale or swallow any cleaning product Protect surrounding surfaces and clothing from exposure When using strong cleaning agents such as bleach or alcohol it is advisable to first test them in an inconspicuous area to be certain they will not damage the upholstery plastic or metal surfaces of the NuSi...

Page 31: ...ds using commercial dry cleaning solvents Ultraleather is a trademark of Ultrafabrics LLC Plastic and Coated Metal Surfaces 1 To remove ordinary dirt Prepare a soapy solution comprised of neutral detergent household dish washing liquid and water Using a soft cloth or sponge apply this soapy solution to the plastic and coated metal surfaces NOTE To remove heavier dirt apply Formula 409 or Fantastik...

Page 32: ... disinfectant products containing sodium hypochlorite common household bleach diluted 1 10 Mayer Savoy with PERMABLOK3 from Spradling Mayer Savoy fabrics with PERMABLOK3 advanced vinyl protection contain an antimicrobial and antibacterial protection on an anti stain finish that is easily cleaned Mayer Savoy with PERMABLOK3 provides exceptional disinfectability using a wide range of cleaning produc...

Page 33: ...www DentalEZ com 866 DTE INFO 30 NuSimplicityTM Chair PN 2717 256E ...

Page 34: ...l circuit board and electrical cabling for recycle as electrical salvage Metal Salvage Remove all aluminum and steel components for recycle as metal salvage Plastic Salvage Remove all plastic components for recycle as plastic salvage Biologically Contaminated Salvage Cuspidor waste lines from the cuspidor and the oral extraction lines should be handled with precaution and disposed of appropriately...

Page 35: ...www DentalEZ com 866 DTE INFO 32 NuSimplicityTM Chair PN 2717 256E ...

Page 36: ... Part Kit No Seamless Seat Cushion 3802 466 Seamless Seat Cushion Ultra 3802 466U Seamless Back Cushion 3802 467 Seamless Back Cushion Ultra 3802 467U Plush Seat Cushion 3802 468 Plush Back Cushion 3802 469 Standard Headrest Cushion 3801 827 Standard Headrest Magnetic Cushion 3801 826 Double Articulating Headrest Cushion Optional 3801 535 Back Substrate Blind Grip Fasteners 3801 742 Seamed Back Cu...

Page 37: ...ww DentalEZ com 866 DTE INFO 34 NuSimplicityTM Chair PN 2717 256E Section VII Parts Lists Diagrams To order parts online visit www dentalezparts com or scan QR code with smartphone DentalEZ Parts Online ...

Page 38: ...crete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical Fast Transient Burst IEC 61000 4 4 2 kV for power supply lines 1 kV for input output lines 2 kV for power supply lines 1 kV for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV...

Page 39: ...romagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the NuSimplicity Chair is used exceeds the applicable RF compliance level above the NuSimplicity Chair should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorientin...

Page 40: ...ion Structures Base Plate Castings Chair Seat and Back Hydraulic System Cylinders Solenoid Valves and Pump Electronics Master Circuit Board and Foot Control Circuit Board Chair Control The upholstery package is covered under this limited warranty for a period of one 1 year from the date of installation Please note the following additional terms of our warranty and return policy Warranties cover ma...

Page 41: ...2500 Highway 31 South Bay Minette Alabama 36507 866 DTE INFO www dentalez com DentalEZ Alabama Inc Printed in USA PN 2717 256E April 2019 ...

Reviews: