Chapter 8 Logging
131
8.3.3.2 Setting the control log recording interval and number
You can configure the sampling interval and number of logs (control log mode) for recording control logs in the
ring buffer.
The number of control logs recorded (control log mode) is set in 1-24 units of 1,250 (1,250 - 30,000).
The sampling interval can be set at 8/16/24/32 ms.
The default setting records 10 seconds of log in the ring buffer (control log number: 1,250; sampling interval: 8
ms).
Configuring with teach pendant
Press F2 (Arm)|F6 (Auxiliary function)|F7 (Usage conditions) and enter values for No.22 and No.23.
WINCAPS III settings
Choose Debug|Controller Settings / Control log acquisition times in online (debugging) mode.
Note
The most recent 1,250 error trigger logs are secured regardless of the number setting.