Chapter 16. Extended Functions
393
*1
R/W: Read and write possible
RO: Read only
Note:
Items #41 through #46 take effect only when the LAN communica-
tions software is installed to the BHT.
.syScnMark
38
Scanning range
marker
(BHT-100Q)
R/W
–
0
Normal mode (Driven by the
trigger switch)
0
–
1
Fixed to ON
–
2
Fixed to OFF
Scanning range
marker
(BHT-100B)
R/W
–
0
Normal mode (Driven by the
trigger switch)
0
–
1
Fixed to OFF
.syVwFindr
39
View finder
(BHT-100Q only)
R/W
.syVFOff
0
OFF
0
.syVFOn
1
ON
.syOptData
40
Option data
(BHT-100Q only)
R/W
.syODOff
0
OFF
0
.syODOn
1
ON
.syLkCnt
41
Retries of establish
link command
R/W
0 to 32767
5
.syLkIntv
42
Intervals between
retries of establish link
command
R/W
1 to 32767 (100 ms to 3276.7 sec.)
5
(500 ms)
.syUlkCnt
43
Retries of release link
command
R/W
0 to 32767
5
.syUlkIntv
44
Intervals between
retries of release link
command
R/W
1 to 32767 (100 ms to 3276.7 sec)
5
(500 ms)
.syUlkTmr
45
Link release period
R/W
0 to 32767 (sec.)
30
.syDvSpd
46
Transmission speed
between the BHT and
LAN-support CU
R/W
5: 115200 bps
5
(115200
bps)
Item number
(PARA%)
System menu item
Attribute
*1
DATA%
, numeric data of
the system menu item
Initial
value
Summary of Contents for BHT-BASIC 100 SERIES
Page 1: ......
Page 161: ...153 Chapter 10 Sleep Function CONTENTS 10 1 Sleep Function 154...
Page 163: ...155 Chapter 11 Resume Function CONTENTS 11 1 Resume Function 156...
Page 173: ...165 Chapter 13 Backlight Function CONTENTS 13 1 Backlight Function 166...
Page 249: ...241 Example CLOSE IF kyIn Y THEN KILL Master Dat END IF Reference Statements CLFILE...