Note:
The oil warning system protects the generator against damages caused by too low oil level in the
engine case. Before the oil level reaches the minimal filling level, the oil lack display will light up and
the system will automatically turn the engine off (the main switch remains on the ON position, if it was
turned into position ON before). If the engine is turned off, or the oil lack display lights up upon
switching on the starter, check the oil level first before looking for other faults.
2. Checking the fuel level
The generator is operated with unleaded gasoline.
Unleaded gasoline leads to less sediments in the engine and the spark plugs and prolongs the
lifetime of the exhaust system.
Please refill gasoline in case of low gasoline level.
Never use old or dirty gasoline or an oil-gasoline mixture.
Avoid dirt and water entering the gasoline tank.
Warning!
Gasoline is highly inflammable and may explode under certain circumstances.
Do not smoke and avoid open fires and sparks during filling of the gasoline tank as well as at
the storage location of the gasoline. Fill up the fuel tank only at well-aerated locations and
when the device is turned off.
Do NOT overfill the tank (gasoline level must be lower than the upper marking).
Do not spill gasoline during filling. Spilled amounts and gasoline vapours may catch fire. In
case of spilled gasoline, make sure that the vapours evaporate before the generator is turned
on.
Avoid long skin contact with gasoline and breathing in gasoline vapours.
fuel tank cap
open
upper level