31
• CX870 system Firm error codes when rewriting. (Check ETHERNET unit)
Error Code
Details of Error code
Coping strategies
A0
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A1
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
A2
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A3
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A4
Login failed
Check the network connection. Carry out the update in an
environment that has little network load.
A6
Error receiving response FirmInfo acquisition
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A7
FirmInfo Get Response TimeOut
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
A8
Net not connected
Check the network connection. Carry out the update in an
environment that has little network load.
A9
Net Connection TimeOut can not get status
Check the network connection. Carry out the update in an
environment that has little network load.
AA
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AB
After download request, Login Failed
Check the network connection. Carry out the update in an
environment that has little network load.
AC
After download request, Login Failed
Check the network connection.Carry out the update in an
environment that has little network load.
AE
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
AF
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B0
Failure of DownLoad
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
B2
Update error
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Failure to update, After the move again 8x0 selfe display retry processing
8. Update mode (by RS232C)
Firmware update using PC via RS232C.
Upgrade by DPMS. No display.
To exit this mode, unplug the power cord.
9. MAC Address rewrite mode
Rewriting the MAC address mode.
Production / development for, there is no detailed description.
To exit this mode, unplug the power cord.
10. Access to development server mode
Production / development for, there is no detailed description.To exit this mode, unplug the power cord.
11. Cooling FAN active
The fan rotates according to the condition of the temperature sensor (s101) as follows.
S101
Fan rolate
T < 55℃
STOP
T ≧55℃
Rolate
Summary of Contents for CEOL Piccolo DRA-N5
Page 17: ...17 5 Remove the MAIN BOARD Shooting of photograph D...
Page 40: ...40 Personal notes...
Page 62: ...62 PCM9211 AMP IC103...
Page 63: ...63 PCM9211 Block Diagram...
Page 64: ...64 PCM9211 Pin Discriptions...
Page 70: ...70 L6565 SMPS IC821 L6565 Block Diagram...
Page 71: ...71 ICE3BR1765J SMPS IC871 ICE3BR1765J Block Diagram...