smartDEN
IP-16R-XX
User Manual
13 Apr 2021
-
42
-
10.1.3. Control
Table 10.3.
Control
OID
Name
Access
Description
Syntax
x
.6.3.1.0
RelaysState
read-write
Access all the relays
with single command
INTEGER32
(0..65535)
x
.6.3.2.0
Reboot
read-write
Reboot the device
INTEGER
(0..255)
x
.6.3.3.0
sysUpTime
read-only
The time (in hundredths
of a second) since the
device was last re-
initialized.
TIMETICKS
10.1.4. Week Schedule
Table 10.4.
Week schedule parameters
Start OID
End OID
Name
Access Description
Syntax
x
.6.4.1.0
...
WeekSchedu
leStartDate
read-
write
Week
Schedule
Start Date
(dd/mm/yyyy)
DISPLAYST
RING
x
.6.4.2.1.2.0
x
.6.4.2.1.2.29
Enabled
read-
write
Week
Schedule
Row Enable
Flag
(Disabled-0,
Enabled-1)
INTEGER {
no(0),yes(1)
}
x
.6.4.2.1.3.0
x
.6.4.2.1.3.29
Outputs
read-
write
Outputs Code
(0..65535),
Output1 - bit
0, ...,
Output16 - bit
15
INTEGER32
(0..65535)
x
.6.4.2.1.4.0
x
.6.4.2.1.4.29
OutputsState read-
write
Outputs Code
(0..65535),
Output1 - bit
0, ...,
Output16 - bit
15
Outputs
State (off-0,
on-1)
x
.6.4.2.1.5.0
x
.6.4.2.1.5.29
Hour
read-
write
Hour (hh:mm) DISPLAYST
RING
x
.6.4.2.1.6.0
x
.6.4.2.1.6.29
WeekDays
read-
write
WeekDays
Code
(0..127),
Sunday - bit
0,
...,
Saturday - bit
6
INTEGER
(0..127)
To reboot the device via SNMP, set the Reboot value to the ASCII code of
the first char of your Web password. For example, if this is the char 'a',
code in decimal is 97.