8.7. Auto-reboot Settings
smartDEN IP-16R-XX
can be used for Auto-rebooting of IP devices (servers, PC
hosts, switches, cameras etc.). In this mode
smartDEN IP-16R-XX
checks the
working state of the device at regular intervals by sending ping requests. After preset
number of successive ping failures
smartDEN IP-16R-XX
performs a predefined
reset/reboot sequence of the monitored device connected to one of the 16 relays.
Figure 8.9.
Auto-reboot configuration page
One of
smartDEN IP-16R-XX
channels can be configured to work in Auto-reboot
mode:
Auto-reboot Mode Enable
- activate this mode;
IP Address To Ping
- the IP address of the device to be rebooted when pings
will fail;
Interval Between Pings, sec
– the time interval between two sequential ping
requests sent to IP address of the monitored device (from 1 to 3600 seconds);