3. Maintenance and Troubleshooting
H-110-200E V00
Page 10
Boiler cleaning & maintenance / 200hours*
Carefully remove the nozzle holder flange and the
electrodes holder (boiler burner head).
*
Clean the small glass in the flange every 50 hours of
use.
Clean the fuel nozzle filter with compressed air and
check the position and wear of the spark electrodes.
Remove the boiler cap by unscrewing the 3 nuts and
clean the deflector with a brush and/or with compressed
air.
Manually take away the interior cap.
Remove the high pressure hoses and unscrew the locking
nuts from beneath. Pull out the boiler coil.
Clean the boiler coil for
residue with a wire
brush.
Vacuum clean the
residue from the boiler
housing.
Summary of Contents for H-110-200E
Page 20: ...4 Spare Part List H 110 200E V00 Page 19 Boiler assembly H 110 200E ...
Page 23: ...4 Spare Part List H 110 200E V00 Page 22 Pump assembly H 110E ...
Page 26: ...4 Spare Part List H 110 200E V00 Page 25 Pump assembly H 200E ...
Page 34: ...4 Spare Part List H 110 200E V00 Page 33 H 200E 220V 60Hz Standard ...