Servicing the Plungers
Disassembly :
1. Remove the plunger retainer nut. (See Fig. 22)
2. Insert the gasket scraper between the copper washer and plunger to remove the washer.
(See Fig. 23)
3. Twist and pull the plunger off the plunger rod.
4. Remove the plunger rod O-ring seal and split back-up ring with the mechanics pick. (See
Fig. 24)
5. Remove brass slinger. At this point clean any thread locker that is left on the plunger rod
and retaining nut threads. (See Fig. 25)
Fig.22
Fig.23
Fig.24
Fig.25