background image

A Crane Co. Company

420 Third Street 

83 West Drive, Brampton

Piqua, Ohio 45356 

Ontario, Canada L6T 2J6

Phone: (937) 778-8947 

Phone: (905) 457-6223

Fax: (937) 773-7157 

Fax: (905) 457-2650

www.cranepumps.com

Limited 24 Month Warranty

Crane Pumps & Systems warrants that products of our manufacture will be free of defects in material and workmanship 
under normal use and service for twenty-four (24) months after manufacture date, when installed and maintained 
in accordance with our instructions.This warranty gives you specifi c legal rights, and there may also be other rights 
which vary from state to state. In the event the product is covered by the Federal Consumer Product Warranties Law 
(1) the duration of any implied warranties associated with the product by virtue of said law is limited to the same 
duration as stated herein, (2) this warranty is a LIMITED WARRANTY, and (3) no claims of any nature whatsoever 
shall be made against us, until the ultimate consumer, his successor, or assigns, notifi es us in writing of the defect, 
and delivers the product and/or defective part(s) freight prepaid to our factory or nearest authorized service station. 
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH RESPECT TO ANY 
PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF MANUFACTURE OR 
AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE. THERE SHALL BE 
NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

 Unless expressly 

stated otherwise, guarantees in the nature of performance specifi cations furnished in addition to the foregoing material 
and workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for 
fi eld performance. Any additional guarantees, in the nature of performance specifi cations must be in writing and such 
writing must be signed by our authorized representative. Due to inaccuracies in fi eld testing if a confl ict arises between 
the results of fi eld testing conducted by or for user, and laboratory tests corrected for fi eld performance, the latter 
shall control. 

RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS 

ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE EXPERIENCE AND 
PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A WARRANTY OF 
SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage (c) lightning 
(d) excessive sand or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any 
modifi cation of the original equipment will also void the warranty. We will not be responsible for loss, damage or labor 
cost due to interruption of service caused by defective parts. Neither will we accept charges incurred by others without 
our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice 
and\or our specifi c recommendations. The purchaser is responsible for communication of all necessary information 
regarding the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR 

ANY OTHER DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO TRAVEL EXPENSES, 
RENTED EQUIPMENT, OUTSIDE CONTRACTOR FEES, UNAUTHORIZED REPAIR SHOP EXPENSES, LOST 
PROFITS, LOST INCOME, LABOR CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES 
ARE CAUSED BY ANY DEFECTS IN MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN 
SHIPMENT. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, 
INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE

.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, 
without our prior written approval.

Summary of Contents for 7150 Series

Page 1: ...nge product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 ww...

Page 2: ...erved CONTENTS SAFETY FIRST 3 A GENERAL INFORMATION 4 Receiving Storage Service Centers B INSTALLATION 4 6 Foundation Mounting Field Alignment Grouting Dowelling Piping Wiring Rotation C OPERATION 6 P...

Page 3: ...not wear loose clothing that may become entangled in moving parts WARNING Keep clear of suction and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection whe...

Page 4: ...check your Deming representative or Crane Pumps Systems Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 B INSTALLATION 1 FOUNDAT...

Page 5: ...ment when the straight edge rests evenly on the coupling rim at all positions Allowance may be necessary for temperature changes and for coupling halves that are not of the same outside diameter Care...

Page 6: ...n arrow on the pump casing Separate the coupling halves then start motor to see that it rotates in the direction required by the pump If it does not reverse any two main leads of the 3 phase wiring to...

Page 7: ...ouble seals and Crane Type B 1 double seal in pumps with Fi No ending in 9 must be lubricated as in item 1 above 3 Pumps with Fig No ending in 3 5 6 and 6H seal chamber may be pressurized with Shell A...

Page 8: ...sleeve mounted on the pump shaft 6 by means of heat shrink fit To remove shaft sleeve dismantle power frame as below place shaft in a vise and proceed as follows 1 With a hand grinder and a thin grin...

Page 9: ...lace capscrews 219 where used SHAFT SLEEVE 14 a Pumps having Fig No ending 3 5 6 6H having shrink fit sleeve 1 After old sleeve has been removed clean shaft with emery cloth and wipe thoroughy to remo...

Page 10: ...moved laterally on the shaft sleeve the drive ball can be inserted in the shaft sleeve recess After drive ball is inserted move seal rotating assembly on the shaft sleeve until compression ring is ce...

Page 11: ...Cover O B Shaft Sleeve Gasket 40 46 51 53 57 59 69 73 204 206 207 208 209 210 211 212 213 215 Deflector Coupling Key Grease Retainer Base Suction Elbow Handhole Cover Lockwasher Brg Casing Gasket Adj...

Page 12: ...49 51 53 57 59 69 73 203 204 206 207 208 209 210 211 212 213 214 215 216 Lip Seal Inboard Lip Seal Outboard Grease Retainer Base Suction Elbow Handhole Cover Bearing Lockwasher Casing Gasket Nameplate...

Page 13: ...o Name Of Part 37 38 40 46 51 59 69 73 203 204 206 207 208 209 210 211 212 Bearing Cover O B Shaft Sleeve Gasket Deflector Coupling Key Grease Retainer Handhole Cover Lockwasher Brg Casing Gasket Name...

Page 14: ...B Item No Name Of Part 37 38 40 46 47 49 51 59 69 73 203 204 206 207 208 209 210 211 212 213 Bearing Cover O B Shaft Sleeve Gasket Deflector Coupling Key Seal Inboard Seal Outboard Grease Retainer Ha...

Page 15: ...49 51 53 57 59 69 73 203 204 206 207 208 209 210 211 213 214 215 216 217 218 Lip Seal Outboard Grease Retainer Base Suction Elbow Handhole Cover Lockwasher Brg Casing Gasket Nameplate Adjusting Lockn...

Page 16: ...44 46 47 48 49 51 57 59 69 71 73 204 206 207 209 210 212 213 215 216 217 Deflector Coupling Half Pump Coupling Half Motor Coupling Key Seal Inboard Coupling Spider Seal Outboard Grease Retainer Suctio...

Page 17: ...ormance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testin...

Page 18: ...t To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by th...

Page 19: ..._ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating _______________...

Page 20: ...alled away from turbulence YES___ NO___ Is level control operating properly YES___ NO___ Is pump fully submerged during operation YES___ NO___ Follow up Corrective Action Required YES___ NO___ Additio...