1.  To prime the pump, press the MANUAL button – the bar at the bottom of the display will 

move from right to left from OFF to AUTO to ON.  When it reaches ON, the pump will 
run until the MANUAL button is pressed again. Use this position to prime the pump.  To 
stop priming press the MANUAL button – the bar at the bottom of the display will move 
from left to right from ON to AUTO to OFF. 

Note: The unit may continue to run in the AUTO position.  The MANUAL button 
must be pressed until the bar at the bottom of the display is over the OFF position to 
stop the pump.

  

 

E.  Setting into Programmed Position

 

1.  Press the MANUAL button until the bar in the bottom of the display moves from the OFF 

to the AUTO position.  If the unit is not in the AUTO position, the program will not be 
executed.  

 

Troubleshooting 

 

Symptom Probable 

Cause 

Remedy 

Pump running when it is not 
programmed to run. 

1.

 

The program, date, or time are set 
wrong. 
 

2.

 

Did not program stop time. 

1.

 

Check the program, date, and time to make sure 
they are set properly. A common mistake could be 
where an AM is supposed to be a PM. 

2.

 

Check the programs for a stop time for each 
program. 

Pump is not priming or not 
holding a prime. 

1.

 

Hole in the tubing from the chemical 
container to the pump head. 
 
 

2.

 

Hole in the squeeze tube in the pump 
head. 

3.

 

Pick up tubing is not sealed to the 
squeeze tube fitting. 

1.

 

Check the tubing from the chemical container to 
the pump head for leaks by feeling the tubing for 
chemical that has leaked out. Replace the tube if 
necessary. 

2.

 

Replace the squeeze tube after inspecting it for a 
possible hole or leak. 

3.

 

Tighten the nuts on the squeeze tube fitting. 

Pump over feeding (using 
too much chemical). Pump 
under feeding (not enough 
chemical). 

1.

 

The programs entered in the unit were 
set wrong. 

2.

 

The batteries are low on power 
 

1.

 

Check the program(s) to make sure they are set 
properly. A common mistake could be where an 
AM is supposed to be a PM. 

2.

 

Replace batteries. 

Pump runs constantly. 

1.

 

Did not match the Event #, Days or 
AM/PM for the stop time. 

 

1.

 

Check the programs for a stop time for each 
program; make sure the events are matched up. 

 

 
 

Warranty 

 

Merchandise Returns 

No Merchandise will be returned for credit without DEMA’S written permission.  Returned merchandise 
authorization number is required in advance of return. 
 

Product Warranty 

DEMA products are warranted against defective material and workmanship under normal use and service 
for one year from the date of manufacture.  This limited warranty does not apply to any products that have 
a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, 
or misapplication.  Rubber and synthetic rubber parts such as “O”-rings, diaphragms, PVC tubing, and 
gaskets are considered expendable and are not covered under warranty.  This warranty is extended only to 

Summary of Contents for SQUIRT DC

Page 1: ...l city county parish provincial or other agencies It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation Fo...

Page 2: ...JACO 2505 25 220 1 81 16 3 25 160 20 SUPER TUBE 81 312 1 81 231 4 EPDM CONE Operational Requirements For indoor use only Main Power 8 D CELL BATTERIES NOT INCLUDED Case Material ABS Product Weight 1 1...

Page 3: ...44 116 2 8 X 3 8 HI LO SCREW 8 81 18 1 6 X 3 8 HI LO SCREW 9 83 16 2 VELCRO PATCH Installation Mount the unit no higher than 6 feet from the chemical container Take into account the proximity to the c...

Page 4: ...sure to push the pump head on tightly so that the tab is grasping the pump head If the tab is not fully engaged there is a possibility the pump head becoming dislodged Correct Incorrect Operation Prog...

Page 5: ...events can be programmed 1 Press and release the TIMER button to enter the programming mode The event number will be in the bottom left corner Note To program a full event a pump start time and stop...

Page 6: ...ck up tubing is not sealed to the squeeze tube fitting 1 Check the tubing from the chemical container to the pump head for leaks by feeling the tubing for chemical that has leaked out Replace the tube...

Page 7: ...fective units or parts should be returned to the factory with transportation prepaid If inspection shows them to be defective they will be repaired or replaced without charge F O B factory DEMA assume...