Squeeze Tube Installation
Install the squeeze tube by removing the pump cover by depressing the tab on the front of the
unit. (1) Place one end of the squeeze tube on the left side of the pump in the slot provided. (2)
Wrap the squeeze tube around the rollers of the pump. (3) Then stretch the squeeze tube so that
the end of the tube goes into the slot provided. (4) Replace the cover on the pump.
(1)
(2)
(3)
(4)
Close Pump Head
The pump head has an added feature which will help to ensure the pump head is retained
properly. When pushing the pump head on, be sure to push the pump head on tightly so that the
tab is grasping the pump head. If the tab is not fully engaged, there is a possibility the pump
head becoming dislodged.
Correct
Incorrect
Operation
Programming the Dispenser
CAUTION:
When the unit is powered the first time, a rechargeable
display back up battery begins charging. When fully charged it
provides approximately 200 hours of reserve time before the display
and program may be lost. If the unit loses power, it will not lose the
program for 200 hours, but it will not run the pump from the
rechargeable display back up battery and will not dispense chemical. If
the unit becomes unplugged from the wall for a short amount of time,
plugging the unit back in will not affect the programming done to the
unit.
Pump head
Push tab up