31
GB
• Only use grinding discs where the
indicated rotational speed is at least
as high as what has been specified on
the name plate of the device.
• Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
• Make sure that the sparks produced
by grinding do not present a danger,
e.g. reach people or ignite flammable
substances.
• Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing
and cutting.
• Never keep the fingers between the
grinding disc and spark protection or
in close proximity to the protective
hoods. There is a risk of crushing.
• The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and
hold the workpiece firmly in order to
avoid slipping which could cause your
hands to come into contact with the
grinding disc.
• The workpiece gets hot during grind-
ing. Do not touch the machined area,
allow it to cool down. There is a risk
of burning. Do not use coolants or the
like.
• If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.
- if the power cable for this equipment
is damaged, it must be replaced
with a special power cable, which is
available from the manufacturer or a
customer service agent of the same.
Residual risks
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage if suitable respiratory
protection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from
swinging hand and arm, in the event
that the device is used over a longer
period of time or is not used and main-
tained properly.
Warning!
During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the
risk of serious or lethal injuries,
we recommend that persons with
medical implants consult their doc-
tor and the manufacturer of their
medical implant before operating
the machine.