background image

9. Production information

38

39

9. Production information

EN

9. 

Production information

NOTE

 

All production information is provided for 

orientation purposes only. The measur-

ing devices and meters provided by 

the electricity supply company are the 

authoritative source of information for 

invoicing.

9.1 

Overview Menu Structure (Display  

Interface)

Start Up messages come up first on start up and then the 

Main menu loop with 4 main parts.
1.  Start Up Messages
2.  Measurement loop (AC, DC, Power and Energy)
3.  System Information loop
4.  Logs
5.  Communication Settings

 

Display Interface should be used only for the Start Up 

settings

 

It is recommended that advanced settings are done via 

the Web Interface if you have the 

ETHERNET

 option.

9.1.1  Startup Menu

SOLIVIA

5.0 TL

DSP   Comm. Red.

0100  0100  0100

Page  Wifi

0100  0100

Start up messages (not the first start up)

After 2 

sec.

After 2 

sec.

After 2 

sec.

Country

XXX

Limited Power

4.6 / 5.0 KW

Insulation Mode

XXX

Resistance

XXX

After 2 

sec.

After 2 

sec.

After 2 

sec.

After 2 

sec.

31/12/2012

23:58

After 2 

sec.

Down to Main Menu (occurs automatically after 2 seconds)

Messages shown during start up:
1.  Firmware used 
2.  Installed country settings  (for a controller)
3.  Limited power:  (for example for Germany: 4.6 kVA)
4.  Max power:  (for example for Germany: 70% rule)
5.  Set values for Insulation monitoring / and used mode 

(warning / alarm)

6.  Date / Time

9.1.2  Main Menu Loop

Main Menu Loop

SOLIVIA

5.0 TL

Logs

Comm. Settings

ID:xxx

Page  Wifi

0100  0100

SEL

SEL

SEL

Logs Start

ENT

Comm. Settings 

Start

ENT

ENT or After 

2 sec.

DSP   Comm. Red.

0100  0100  0100

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

AC: xxx V xx.x A

 xx.xx Hz xxxx W

DC: xxx V xx.x A

          xxxx W

Today DC

xxxxx Wh

Today AC

xxxxx Wh

DC Life Energy

xxxxxx KWh

AC Life Energy

xxxxxx KWh

cos phi x.xx

PR xxx %

ENT or After 

2 sec.

 

Measurement Information Section

System Information Section

Country

XXX

Limited Power

4.6 / 5.0 KW

ENT or After 

2 sec.

Insulation Mode

XXX

Resistance

XXX

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

SEL

31/12/2012

23:58

ENT or After 

2 sec.

9.1.3  Measurement Loop

SEL

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

AC: xxx V xx.x A

 xx.xx Hz xxxx W

DC: xxx V xx.x A

          xxxx W

Today DC

xxxxx Wh

Today AC

xxxxx Wh

DC Life Energy

xxxxxx KWh

AC Life Energy

xxxxxx KWh

cos phi x.xx

PR xxx %

ENT or After 

2 sec.

Measurement Information Section

Provides the following information on AC / DC side:

 

AC values

 

DC values

 

Today / Lifetime Energy produced

 

Actual Cos phi

9.1.4  System Information Loop

SOLIVIA

5.0 TL

Page  Wifi

0100  0100

SEL

DSP   Comm. Red.

0100  0100  0100

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

System Information Section

Country

XXX

Limited Power

4.6 / 5.0 KW

ENT or After 

2 sec.

Insulation Mode

XXX

Resistance

XXX

ENT or After 

2 sec.

ENT or After 

2 sec.

ENT or After 

2 sec.

31/12/2012

23:58

ENT or After 

2 sec.

Provides:

 

Firmware version

 

Country name

 

Limited power / Max Power

 

Set monitoring 

 

Mode for control of insulation

9.1.5  Logs and Communications Menus

Logs

Comm. Settings

ID:xxx

SEL

Logs Start

ENT

Comm. Settings 

Start

ENT

 

SEL

 

9.1.5.1  Logs Menu

Logs Start

Logs

Internal Logs

          Enter

Grid report

          Enter

SEL

Internal Logs 

Start

ENT

Grid report Start

SEL

Comm Settings

          Enter

ENT

Internal Logs 

Start

01 : Grid   Freq

  Under  Rating

02 : Empty

16 : Empty

SEL

SEL

SEL

Internal Logs

          Enter

Internal 
Logs

01:

31/12/2012 23:58

ENT or After 

2 sec.

SEL

02:

00/00/0000 00:00

ENT or After 

2 sec.

SEL

16:

00/00/0000 00:00

ENT or After 

2 sec.

SEL

Logs menu shows the following information:

 

Internal Logs

Summary of Contents for SOLIVIA 30 EU T4 TL

Page 1: ...Operation and installation manual SOLIVIA 3 0 EU T4 TL SOLIVIA 5 0 EU T4 TL preliminary...

Page 2: ...the device All information and specifications can be modified without prior notice Within this manual there may be symbols used that indicate that ETHERNET or WIRELESS function is required to utilize...

Page 3: ...n features ETHERNET 19 5 7 Electrical connections 20 5 7 1 Overview 20 5 7 2 DC connections and DC switch 21 5 7 3 AC connection 21 5 7 4 Communications Module RS485 ETHERNET WiFi 21 5 7 4 1 RS485 int...

Page 4: ...unication module ETHERNET WIRELESS 36 8 4 Next steps 37 9 Production information 38 9 1 Overview Menu Structure Display Interface 38 9 1 1 Startup Menu 38 9 1 2 Main Menu Loop 38 9 1 3 Measurement Loo...

Page 5: ...ionality must be present to access the web interface 1 3 Warnings and symbols The following section explains the warnings and symbols used in this manual DANGER Indicates a dangerous situation An acci...

Page 6: ...lar inverter during operation This potentially fatal voltage is still present for five minutes after all power sources have been discon nected Never open the solar inverter Always disconnect the solar...

Page 7: ...sse ausreichend abgedichtet werden Nicht genutzte Anschl sse m ssen mit den am Solar Wech selrichter angebrachten Abdeckkappen verschlossen werden Italiano Indicazioni di sicurezza generali PERICOLO P...

Page 8: ...este manual Antes de realizar trabajos en el inversor solar se debe separar el inversor solar de la red y de los m dulos FV El inversor solar presenta un valor de corriente de fuga elevado El conducto...

Page 9: ...en m Najprv odpojte sie aby sol rny invertor nemohol dod va iadnu al iu energiu Potom rozpojte odpojova DC Zabezpe te DC pr pojky pred dotykmi Sol rny invertor mo no bezpe ne a norm lne prev dzkova i...

Page 10: ...st te prevenci proti z sahu bleskem a to dodr ov n m ustanoven platn ch ve va zemi Povrch sol rn ho st da e m e b t velmi hork Sol rn st da je t k Sol rn st da je nutno zvedat a p en et v dy ve dvou K...

Page 11: ...njury due to heavy weight The solar power inverter is heavy see Chapter 13 Technical Data Incorrect han dling can lead to injuries The solar power inverter must always be lifted by at least two people...

Page 12: ...d in the following table SOLIVIA 3 0 TL and 5 0 TL inverter packing list Object Qty Description PV Inverter 1 3 kVA or 5 kVA solar inverter User Manual 1 The Instruction to provide the information of...

Page 13: ...on Module Communication modules are available in three configurations depending on which inverter is ordered Type 1 is the stan dard default module that has the RS485 communication only Type 2 is a mo...

Page 14: ...tion Hazardous voltage is still present 5 minutes after all power sources have been disconnected Never open the solar power inverter The solar power inverter contains no components that are to be main...

Page 15: ...terface ETHERNET interface and WiFi module depends on the communications module type See the following section for further details 5 7 4 1 RS485 interface EIA485 The two RS485 interfaces are used to c...

Page 16: ...s comes in multiple languages Accessible by Ethernet or WiFi connection IP address Ethernet 169 254 1 100 or WiFi 169 254 2 100 3 level of users are available Guest pwd guest Owner pwd owner Installer...

Page 17: ...assumed temperature More exact information on tempera ture dependency is provided in the PV module data sheet The feed in voltage range of the solar power inverter defines the range of input voltages...

Page 18: ...inte grated internal web interface Production information ETHERNET Production information is available for the actual day week month etc The production information is saved each month Warning and fai...

Page 19: ...degree of pro tection and can be installed indoors and in protected outdoor areas Note the Operating temperature range at full power without derating and the maximum operating tem perature range When...

Page 20: ...Mounting plate WARNING Danger of injury due to heavy weight The solar power inverter is heavy Incorrect handling can lead to injuries The solar power inverter must always be lifted by at least two peo...

Page 21: ...ting nuts and washers for fastening the solar power inverter to the mounting plate The following items are also required Screws 5 mm dowels for fastening the mount ing plate to the wall 12 pcs M5 scre...

Page 22: ...s kit allow you to meet the DC protection and signal requirements specified in UTE C 15 712 1 Multi Contact UTE Kit Delta Part Num ber Multi Contact UTE kit for SOLIVIA EU G4 TR EOE90000341 7 3 3 Esta...

Page 23: ...dule kit is supplied in the scope of delivery Ethernet RS485 1 RS485 2 Antenna Rubber Seal Plug Claw Nut Fig 7 10 Assembly of the communications module The three openings for the cable feed through ar...

Page 24: ...VDE 126A1 Germany VDE 0126 1 1 A1 x FR UTE France UTE 15 712 1 x NL Netherlands x PL Poland SPAIN RD 1699 Spain RD 1699 2011 x SPAIN Spain RD 1663 2000 x UK G83 1 United Kingdom UK G59 2 United Kingdo...

Page 25: ...Guest Owner Installer Each level will have varied functions with Guest hav ing access to basic information and Installer with more advanced user rights For more info please see Chapter 9 Production I...

Page 26: ...x xx Hz xxxx W DC xxx V xx x A xxxx W Today DC xxxxx Wh Today AC xxxxx Wh DC Life Energy xxxxxx KWh AC Life Energy xxxxxx KWh cos phi x xx PR xxx ENT or After 2 sec Measurement Information Section Sys...

Page 27: ...r is master of Guest and Installer is the master of Owner and Guest User Levels Guest Owner Installer Example of the log in page Three user levels are avail able Guest Owner or Installer The user leve...

Page 28: ...responds to a power gradient of 83 3 Hz User can set all necessary settings to meet the require ments from network operator P 0 Gradient 40 Pm Hz Pm Fstart 50 2Hz Power vs frequency curve for VDE AR N...

Page 29: ...EC62109 2 Minimum Value R VMAX PV 30 mA 33K VDE0126 The array insulation resistance to ground shall be not less than 1 k V with respect to the maximum dc input voltage as specified by the manufacturer...

Page 30: ...n AC plug and make sure it connects to inverter 3 Replace fuses and check all switching devices in boost inverter stages Grid Volt Under Rating 1 Actual utility voltage is under the UVR setting 2 Inco...

Page 31: ...ace the defective relay s 2 Check the driver circuit inside the inverter 3 Check the Vgrid and Vout voltage detection accuracy Message Possible cause Action Bus Unbalance 1 Not totally inde pendent or...

Page 32: ...Incorrect han dling can lead to injuries The solar power inverter must be lifted and carried by at least two people Or use an appropriate lifting device such as a crane 12 1 Decommissioning 1 Switch...

Page 33: ...ass I Configurable trip parameters Yes 3 Isolation monitoring Yes Overload behavior Current limiting power limiting ENS Grid connection guidelines DIN VDE 0126 1 1 RD 1699 2011 RD1633 2000 UTE C15 712...

Page 34: ...ating elevation 2 000 m above sea level 1 Cos Phi 1 VA W 2 AC voltage and frequency range will be programmed according to the individual country requirements 3 Ethernet communication module required t...

Page 35: ...UR 4 6 10 3 6 32 0014P0001 UR 5 5 9 32 0016P0001 UR DC Plug 1 5 2 5 14 3 6 32 0011P0001 UR 5 5 9 32 0013P0001 UR 4 6 10 3 6 32 0015P0001 UR 5 5 9 32 0017P0001 UR MultiContact UTE kit The Multi Contact...

Page 36: ...r Rating R Phase F42 CT current sensor Fail A F45 HW OOCP Circuit F50 Zero Cross Circuit Fail F56 Hardware Incompatibility F60 PV1 Current Over Rating F70 PV1 Current Transient Over Rating Error E01 O...

Page 37: ...55 Certificates EN 15 Certificates Please visit the web site at www solar inverter com to find all applicable certificates for the SOLIVIA 3 0 TL 5 0 TL solar inverters...

Page 38: ...upport greece solar inverter com 49 7641 455 549 Israel support israel solar inverter com 49 7641 455 549 Italy supporto italia solar inverter com 800 787 920 Free Call The Netherlands ondersteuning n...

Reviews: