11
6.8
Interface connection RS485 (EIA485)
The interfaces not used must always be closed off. In case of utilization of an interface, only the
counterpart fitting on the interface connector is to be employed.
Mating connector supplier HARTING Deutschland GmbH & Co. KG (P.O. 2451, D-32381 Minden;
www.harting.com).
Order designation: 09 45 145 1510, Cable Manager Blue IP67 Push-Pull Data Plug
09 45 145 1500, Cable Manager White IP67 Push-Pull Data Plug
-
~
-
~
-
~
-
~
230 V - House connection line
RS485 (EIA485) - Connection
Datalogger
RS485 (EIA485)
terminating resistor
6.7.3
Efficiency
The best efficiency of the solar inverter is obtained at input voltages >250 V.
84 %
86 %
88 %
90 %
92 %
94 %
96 %
0 W
400 W
800 W
1200 W
1600 W
2000 W
2400 W
2500 W @ 125 V
2500 W @ 250 V
2500 W @ 350 V
2500 W @ 450 V