8.3.7.3 Submenu S: Firmware
More detailed information on the firmware menu within the submenu S (Setup).
Submenu Setup
Firmware
S -> Firmware
AC-Ctrl maj.min.bug
Down
Down
Down
Up
Up
Up
Down to 4
3
Up to 3
4
ESC
ESC
ESC
ESC
ENTER
S -> Firmware
DC-Ctrl maj.min.bug
S -> Firmware
SC-Ctrl maj.min.bug
S -> Firmware
Display-Ctrl maj.min.bug
9.
Diagnostics and data evaluation
9.1
Malfunction rectification
The solar inverter is provided with an automatic diagnostics system which indepen-
dently identifies certain faults and which can make them visible on the display.
Troubleshooting in the field
In principle, it is always worth attempting a reset by reinitializing the solar inverter
whenever an error message appears on the display.
To reset the device, proceed as follows:
1. Isolate the solar inverter from the grid (open automatic circuit breaker).
2. Switch off the DC disconnector.
3. Wait: approx. 1 minute.
4. Switch DC disconnector back on.
5. Switch in grid (close automatic circuit breaker).