6
Quick installation guide for RPI M6A M8A M10A inverters
Planning the Installation
5
>20 cm
>20 cm
>20 cm
>20 cm
>20 cm
►
Ensure adequate air circulation Hot air must be able
to dissipate upward. Keep sufficient space around
each inverter
►
Do not install inverters directly above one another
Otherwise, the upper inverter is warmed up by the
lower one
►
Consider the
operating temperature range
(see sec-
tion “Technical Data”)
When the operating temperature range is exceeded,
the solar inverter reduces the amount of power gener-
ated
Ambient temperature and air circulation
Outdoor installations
►
The solar inverter has protection
degree IP65 and can be installed
indoors or in protected outdoor
areas (that means outdoor but
protected by a roof against direct
sun, rain or snow)
►
Mount the solar inverter vertically
Where to mount the inverter
??
??
✔
✘
✘
►
Mount the solar inverter so that the
LEDs and display can be easily seen
and that the buttons can be operated
Make sure the reading angle and instal-
lation height are sufficient.
►
Always use the mounting plate
supplied with the inverter
►
Check that the wall is capable of
bearing the heavy weight of the
inverter
►
Use dowels and screws that are
suitable for the wall material and
the heavy weight
►
Mount the inverter on a vibration-
free wall to avoid disruptive
vibrations
►
Possible noise emissions can be
disruptive when the inverter is
used in living areas or in buildings
with animals Therefore, choose
your installation location carefully
Mounting orientation