background image

PMT2 Panel Mount Power Supply 

PMT2 150W series / PMT-

V150W2C

□□

 

TECHNICAL DATASHEET

 

 

  

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.

 

  www.DeltaPSU.com (September. 2022, Rev. 02)  

 

1

 

                                                                                                              

PMT2

 

Highlights & Features 

  Household appliance approvals according to IEC/EN               

60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16 

  Universal AC input voltage range  

  No load power consumption < 0.3 W  

  Low profile design: 30 mm height  

  OVC III, Pollution Degree 3 

  Wide operating temp -30°C ~70°C (Support -40°C cold start) 

  Conforms to harmonic current IEC/EN 61000-3-2, Class A 

  High MTBF > 700,000 hrs per Telcordia SR-332 

  Compliance with SEMI-F47 

 

 Safety Standards 

 

 

  

 

 

 

 

 CB Certified for worldwide use 

 

Model Number:

   

PMT-

V150W2C

☐☐

 

Unit Weight:

 

 

0.392 kg (0.864 lb) 

Dimensions (L x W x H):

  159 x 97 x 30 mm 

   

 

 

(6.26 x 3.82 x 1.18 inch)

 

General Description 

PMT 2

nd

 generation (PMT2) power supplies is designed in a low 30mm profile and accepts universal AC input.  The highly efficient 

convection cooling construction can operate from -30°C to 70°C. The single output model is competitively priced for general industrial 

and ITE applications. It complies to major safety approvals such as IEC/EN 60335-1, IEC/EN 61558-2-16, IEC 60950-1 & IEC/EN/UL 

62368-1.

 

 

Model Information 

PMT2 Panel Mount Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

PMT-12V150W2C

☐☐

 

90-264 Vac  

12 Vdc 

12.5 A 

PMT-15V150W2C

☐☐

 

15 Vdc 

10.0 A 

PMT-24V150W2C

☐☐

 

24 Vdc 

6.5 A 

PMT-30V150W2C

☐☐

 

30 Vdc 

5.0 A 

PMT-36V150W2C

☐☐

 

36 Vdc 

4.3 A 

PMT-48V150W2C

☐☐

 

48 Vdc 

3.3 A 

 

Model Numbering 

 

 

 

 

 

 

 

CC code 

PM 

T – 

150W 

 

 

Panel 

Mount 

Product Type 
T – Enclosed 

 

Output Voltage 
12 – 12 V 
15 – 15 V 
24 – 24 V 
30 – 30 V 
36 – 36 V 
48 – 48 V 
 

Output Power  Single Phase 

with Low Profile 

Family Code: C 
With No PFC, & 

Full range AC 

Input 

Connector Type 
A – Terminal Block 

Blank – Without 

connector cover & 

coating. 

B – With single 

side coating.*

1

 

*1 : 12 V / 24 V models only 

Summary of Contents for PMT-12V150W2C Series

Page 1: ...eneration PMT2 power supplies is designed in a low 30mm profile and accepts universal AC input The highly efficient convection cooling construction can operate from 30 C to 70 C The single output mode...

Page 2: ...Vdc 1 36 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 10 8 13 2 Vdc 13 5 16 5 Vdc 21 6 26 4 Vdc 27 0 33 0 Vdc 32 4 39 6 Vdc 43 2 52 8 Vdc Output Current 0 12 5 A 0 10 0 A 0 6 5 A 0 5 0 A 0 4 3 A 0 3...

Page 3: ...G for a duration of 11 ms 3 shocks for each 3 directions Operating IEC 60068 2 27 Half Sine Wave 10 G for a duration of 11 ms 3 shock for each 3 directions Vibration Non Operating IEC 60068 2 6 Rando...

Page 4: ...55014 2 EN BS EN 61000 6 1 Electrostatic Discharge IEC 61000 4 2 Level 4 Criteria A1 Air Discharge 15kV Contact Discharge 8kV Radiated Field IEC 61000 4 3 Level 3 Criteria A1 80 MHz 1 GHz 10V M with...

Page 5: ...EET All parameters are specified at 25 C ambient and nominal AC input unless otherwise indicated www DeltaPSU com September 2022 Rev 02 5 Block Diagram Device Descriptions 1 Input Output terminal bloc...

Page 6: ...l AC input unless otherwise indicated www DeltaPSU com September 2022 Rev 02 6 Dimensions L x W x H 159 x 97 x 30 mm 6 26 x 3 82 x 1 18 inch Wire AWG Table Current rating for PVC Wire AWG 6AWG 52 5A 2...

Page 7: ...mperature at 30 C 3 If the output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off unti...

Page 8: ...is surface belongs to customer s end system or panel where the power supply is mounted Connector Base Mounting Horizontal If the device has to be mounted in any other orientation please contact info d...

Page 9: ...e terminals while power is being supplied Risk of electric shock Prevent any foreign metal particles or conductors from entering the device through the openings during installation It may cause Electr...

Page 10: ...e specifications It is not recommended to prolong the duration of Io when it is 110 but 100 since it may cause damage to the PSU Short Circuit Protection Auto Recovery The power supply s output OLP OC...

Page 11: ...ion for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the product before placing an order wit...

Reviews: