107533 Rev. A
5
C.
4
3
Adjust temperature limit stop
Turn on water supplies; LET THE WATER RUN AT
BOTH FULL HOT AND FULL COLD TO ENSURE
THE WATER IS RUNNING AS HOT/COLD AS
POSSIBLE. Place a thermometer in a plastic
tumbler, and hold the tumbler in the water stream.
Place the temperature knob (1) onto the splines
(2), then rotate the temperature knob counter-
clockwise until you achieve your maximum desired
temperature from the outlet (not more than 120°
or the lower temperature mandated by your local
plumbing code).
If max temperature is not achieved before limit
stop (3) on temperature knob (1) meets the limit
stop (4) on the volume control handle. Remove
the temperature control knob (1) from splines (2).
Rotate temperature control knob (1) clockwise.
Place temperature control knob (1) back onto
splines (2) and continue to rotate counter-clockwise
until maximum desired temperature is achieved.
Remove the temperature knob (1) and replace onto
thesplines (2), making sure that the temperature
knob limit stop (3) hits against the volume handle
limit stop (4) as shown.
1
2
4
3
Installation and Adjustment of the Temperature Knob. Failure to do so may cause injury.
4
Valve Trim Installation
A1.
1
2
3
Temperature handle Installation
Secure temperature control knob (1) with screw
(2). See next step for securing temperature control
cover (3).
Snap temperature control cover over temperature
control knob by first aligning smaller tab (1) on
cover with receiving slot (2) on temperature knob.
Swing larger tab (3) to engage with snap feature
(4). Note: If dis-assembly is required, reverse
this motion, disengaging larger tab (3) from snap
feature (4) first.
4
2
1
3
Temperature Handle Installation Step A1 or A2 or A3.
Diverter Handle Installation Step B.