38
useful for debug purposes.
Type
Fault/Status
CAN
Report
Active
Deactive
Status
Chrgr_Prof_
ChargeEnd
0x5Dx,
bit8
Charge has ended due to
Status
Chrgr_Prof_Phase_
AhLim
0x5Dx,
bit10
The number of amp hours
returned to the battery is too
high for the charging stage.
Remove source of fault and
recycle DC on the WSB
Status
Chrgr_Prof_Phase_
Imax
0x5Dx,
bit11
Current has exceeded the
maximum allowed by the
Status
Chrgr_Prof_Phase_
Imin
0x5Dx,
bit12
Current is below the
minimum allowed by the
Status
Chrgr_Prof_Phase_
Timeout
0x5Dx,
bit13
The charge stage is taking
too long.
Remove source of fault and
recycle DC on the WSB
Status
Chrgr_Prof_Phase_
Vmax
0x5Dx,
bit14
Voltage has exceeded the
maximum allowed by the
Status
Chrgr_Prof_Phase_
Vmin
0x5Dx,
bit15
Voltage is below the
minimum allowed by the
Status
Chrgr_Prof_
PhaseComplete
0x5Dx,
bit16
Status
Chrgr_Prof_
PhaseError
0x5Dx,
bit17
occurred