8
Quick Installation Guide for Solar Power Inverter M50A_12s EU V4 EN 2018-10-24
Installation clearances and air circulation
>30 cm
>30 cm
> 80 cm
>30 cm
>20 cm
>30 cm
>30 cm
> 80 cm
>20 cm
>30 cm
► Ensure sufficient air circulation. Warm air must be able to
escape from below
► Leave enough space around each inverter
► Do not install inverters above one another so that they do
not heat each other
► Note the
Operating temperature range without derating
and the
Operating temperature range
When the
Operating temperature range without derating
is exceeded the inverter reduces the AC power fed into the
mains
When the
Operating temperature range
is exceeded, the
inverter stops feeding AC power into the mains
This is normal operating behavior for the inverter and is
necessary to protect the internal electronics
Transporting and lifting the inverter
WARNING
Heavy weight
The inverter is very heavy
► The inverter must be lifted and carried by
at least 3 people or using appropriate lifting
gear
Planning the installation