background image

Chapter 2 Settings and Measurements

   

LD-E

 

Operation Manual

 

2-3 

Single point teaching (window comparison mode) 

 

  Single point teaching is used for the distance between the reference plane of the detection object, the 

method of setting the upper and lower limits, and the output between the upper and lower limits. 

  After the reference plane of the detection object is taught 

  1_SL = The height of the detection object minus 2 times the hysteresis 

  2_SL = The height of the detection object plus 2 times the hysteresis 

 

                                       

 

    

 

1. With the detection object, press 

  twice.

 

(1

st

 time: TEACH mode, 2

nd

 time: teaching)

 

   

 

 

     2. After teaching, press 

  once to leave. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LD-100E-M22

Page 1: ...Names and Functions 1 1 1 3 Installation 1 2 Chapter 2 Settings and Measurements 2 1 2 1 Display Operation 2 1 Chapter 3 Software Operation 3 1 3 1 Communication Setting 3 1 Chapter 4 Communication S...

Page 2: ...optional 2 Laser label 3 Simple instruction sheet Laser Label Description 1 2 Part Names and Functions Exterior Positive Side Laser light emitting area Laser light receiving area Panel setting and di...

Page 3: ...ation Manual 1 2 Laser Indicator Indicator Color Description Laser indicator Blue light Start laser on OUT Green light DO IN Yellow light DI Negative Red light Negative 1 3 Installation Dimension unit...

Page 4: ...Chapter 1 Product Profile LD E Operation Manual 1 3 Wiring Instructions...

Page 5: ...following instructions when installing products 1 When products cling to devices install the products in parallel with the devices to assure product performance 2 When the shape of an inspection obje...

Page 6: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 1 Chapter 2 Settings and Measurements 2 1 Display operation Display instruction...

Page 7: ...sic teaching 2 point teaching The teaching point of second point is greater than the first point 2 hysteresis Hys size 1 2 1 In a state of background press 2 When there is a detection object press Whe...

Page 8: ...e method of setting the upper and lower limits and the output between the upper and lower limits After the reference plane of the detection object is taught 1_SL The height of the detection object min...

Page 9: ...set the detection output to _P_2 2 point teaching When executing use detection objects with different distances P 1 P 2 1 When there is a detection object P 1 press the first to enter the teaching mod...

Page 10: ...tween 2nd time and 3rd time First come to the advanced setting set the detection output to _P_3 3 point teaching 1 When there is a detection object P 1 press the first to enter the teaching mode and p...

Page 11: ...for 6 seconds Advanced Mode Press the down button for 3 seconds to get in the menu of advanced settings After entering press the down button for 3 seconds to return to the measurement screen Initial s...

Page 12: ...f 1_SL is 1_SL Hys External input setting External input setting no function zero laser off update data only when triggered Timer setting Timer setting The timer setting interval is 0 1000ms no timing...

Page 13: ...ormat setting ASCII 8 N 1 ASCII 8 O 1 ASCII 8 E 1 ASCII 8 N 2 ASCII 8 O 2 ASCII 8 E 2 RTU 8 N 1 RTU 8 O 1 RTU 8 E 1 RTU 8 N 2 RTU 8 O 2 RTU 8 E 2 ASCII 7 O 1 ASCII 7 E 1 ASCII 7 O 2 ASCII 7 E 2 Statio...

Page 14: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 9 Steps...

Page 15: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 10...

Page 16: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 11...

Page 17: ...tings and Measurements LD E Operation Manual 2 12 Analog output The analog output range is 4 20mA Distance from the closest distance to the farthest distance absolute distance Digital output timer fun...

Page 18: ...Chapter 3 Software Operation LD E Operation Manual 3 1 Chapter 3 Software Operation 3 1 Communication Setting Install the laser displacement and installation file Next Next...

Page 19: ...Chapter 3 Software Operation LD E Operation Manual 3 2 Next Close...

Page 20: ...m waveform acquisition parameter setting and reading Language Language switch English Traditional Chinese Simplified Chinese Information Laser displacement information display Station number model ser...

Page 21: ...the communication format Scanning Step1 Set up the port Step2 Select RTU ASCII mode Step3 Select the station number range Step4 Start scanning Information area After scanning the information of each...

Page 22: ...ual 3 5 Real time data operation area Start Start to read the data and the data will be read according to the selected LD Zero The LD is reset to zero Reset to zero The default value is reset to zero...

Page 23: ...e laser displacement and only one data can be displayed at a time Displacement Display the absolute displacement of the laser Storage quantity setting Can store the relationship between time and locat...

Page 24: ...splay wave weight position Shutter Level Show exposure Exposure setting Can be set to use manual or automatic exposure manual exposure can set the exposure level 0 100 Start Start measuring Capture mo...

Page 25: ...Chapter 3 Software Operation LD E Operation Manual 3 8 Parameter reading and writing operation area...

Page 26: ...ed 1 to 127 Function Code 03H Read the contents of the register 06H Write 1 byte to the address Address Function code Name Description 1000H R W 03H 06H Device address Device address 1 127 1002H R W 0...

Page 27: ...CH Reserved 100DH R W 03H 06H Two_SL position Comparator upper limit position unit 0 1mm 100EH Reserved 100FH R W 03H Weight position Weight position on PD 1010H R 03H Exposure class Exposure level in...

Page 28: ...3H 06H Hysteresis setting Hys LD 500E LD 500E LD 220E LD 100E unit 0 1mm 1019H R W 03H 06H Automatic manual adjustment of exposure level 0x01 Automatic adjustment 0x02 Manual adjustment 101AH R W 03H...

Page 29: ...ADR 01H ADR 01H CMD 03H CMD 03H CMD 06H CMD 06H Starting data address 10H Number of data count by byte 04H Starting data address 10H Starting data address 10H 04H 00H 00H Number of data word Bit 00H S...

Page 30: ...ce Communication method Digital I O Modbus and RS485 Support 9 600 14400 19200 38400 57600 115200bps Default value 15200bps Support format RTU ASCII 8 N 1 8 N 2 8 O 1 8 O 2 8 E 1 8 E 2 7 O 1 7 E 1 7 O...

Page 31: ...e 25 C 65 C Ambient Humidity 30 85 Enclosure Rating IP67 Ambient Light Resistance 3000 lux or less Vibration Resistance 10 55 Hz 1 5mm 3 axes for 2 hours Insulating Resistance 20 M or more 500VDC With...

Page 32: ...ity of human injury eyes skin etc please be sure to observe the followings The product doesn t have automatically stop laser emitting device after dismantling therefore please do not disassemble it Ca...

Page 33: ...ty 1 Any product failure caused by improper conditions environment operation and operation methods not described in operation manual and user manual 2 Any failure due to product defects such as custom...

Reviews: