Chapter 4 Communication Setting
LD-E Operation Manual
4-3
0x0F:
Window size 15
1014H (R/W)
(03H,06H)
Output delay
mode setting
0x01: Normal output mode (Default)
0x02: Off-delay
0x03: On-delay
0x04: One-shot
1015H (R/W)
(03H,06H)
Output delay time
Range:
0x0000~0x03E8: (0~1000ms)
0x05 (Default value)
1016H (R/W)
(03H,06H)
Action output
Normally open/
Normally closed
0x01: Normally closed (Default value)
0x02: Normally open
1017H (R/W)
(03H,06H)
External input
function
0x01: No function (Default value)
0x02: Zero function
0x03: Turn off the laser
0x04: Trigger function
1018H (R/W)
(03H,06H)
Hysteresis setting
(Hys)
LD-500E
、
LD-500E
、
LD-220E
、
LD-100E:
unit: 0.1mm
1019H (R/W)
(03H,06H)
Automatic/
manual
adjustment of
exposure level
0x01: Automatic adjustment
0x02: Manual adjustment
101AH (R/W)
(03H,06H)
Manual exposure
setting hierarchy
Exposure level setting in manual mode
0x01~0x64 (1~100)
101BH (R/W)
(03H,06H)
Detection output
setting
0x00: General detection mode
0x01: 1 point teaching (window comparison
mode)
0x02: 2 point teaching (window comparison
mode)
0x03:
3 point teaching (window comparison
mode)
101CH ~ 101DH
(R)
(03H)
Read firmware
version
Read firmware version
101EH (R)
(03H)
DO status read
0x00 : Not output
0x01: Start output
101FH (R)
(03H)
DI
status read
0x00 : Not input
0x01: Start input
10C7H (R)
(06H)
Restore factory
settings
0x01: Restore factory settings
Summary of Contents for LD-100E-M22
Page 4: ...Chapter 1 Product Profile LD E Operation Manual 1 3 Wiring Instructions...
Page 14: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 9 Steps...
Page 15: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 10...
Page 16: ...Chapter 2 Settings and Measurements LD E Operation Manual 2 11...
Page 19: ...Chapter 3 Software Operation LD E Operation Manual 3 2 Next Close...