57
Installation Instructions for the Hybrid E5 Battery Storage System EU V1 EN 2018-09-17
Technical specifications
Power meter, Smart Monitor
P1E power meter
P3E power meter
Delta model name
P1E
P3E
Communication
WLAN (N1) / RS485
Status display
LED
Nominal operating voltage (L – N)
100 V
AC
... 240 V
AC
230 V
AC
Operating voltage range (L – N)
85 V
AC
... 264 V
AC
130 V
AC
... 260 V
AC
Maximum operating current
120 A
Frequency range
45 ... 65 Hz
Maximum power consumption without/with WiFi
2 W / 4 W
3 W / 6 W
Operating temperature range
-20 ... +50 °C
Storage temperature range
-20 ... +60 °C
Relative humidity
30 ... 85%, non-condensing
Dimensions
93 x 47.3 x 66.5 mm
93 x 70 x 66.5 mm
Weight
145 g
200 g
Protection degree
IP20
Safety standard
IEC 60950-1
Emissions
EN 55022, Class B
Smart Monitor
Delta model name
R4E
Nominal operating voltage
1)
12 V
DC
Operating voltage range
10 ... 16 V
DC
Power consumption
<6 W (without USB connection)
Display
7 inch TFT-LCD touchscreen
800 x 480 pixels, 24 Bit RGB
Communication
RS485 / WiFi
Operation
Operating temperature range
-20 ... +50 °C
Storage temperature range
-20 ... +60 °C
Relative humidity
30 ... 85%, non-condensing
Dimensions
120 x 190 x 32 mm
Weight
440 g
Protection degree
IP20
Safety standard