background image

INNO

V

A

TION  |  MANUF

AC

TURER  |  DE

SIGN  |  SOL

UTION

WWW.DELTAMEMBRANES.COM

 

WWW.DELTAMEMBRANES.COM

 

WWW.DELTAMEMBRANES.COM

 

WWW.DELTAMEMBRANES.COM

 

JUL

Y

 2022

DELTA
FOUL V3 

INSTALLATION 

GUIDE

JUL

Y

 2022

JUL

Y

 2022

Summary of Contents for FOUL V3

Page 1: ...M A N U FA C T U R E R D E S I G N S O LU T I O N WWW DELTAMEMBRANES COM WWW DELTAMEMBRANES COM WWW DELTAMEMBRANES COM WWW DELTAMEMBRANES COM J U LY 2 0 2 2 DELTA FOUL V3 INSTALLATION GUIDE J U LY 2 0 2 2 J U LY 2 0 2 2 ...

Page 2: ...er drainage or weather conditions should be examined more frequently we recommend every 6 months Sump pumps being mechanical devices may fail if not maintained which could lead to a flooded basement and costly repairs Regular servicing of sump pumps will increase efficiency and extend the life of the pump All Delta Membrane pump systems can be maintained and serviced by our recommended service com...

Page 3: ...lation Of Chamber 5 0 INSTALLATION OF CHAMBER SECTION A 5 1 INSTALLATION OF CHAMBER SECTION B 5 2 INSTALLATION OF CHAMBER SECTION C 5 3 INSTALLATION OF CHAMBER SECTION D1 5 4 INSTALLATION OF CHAMBER SECTION D2 5 5 INSTALLATION OF CHAMBER SECTION D3 5 6 INSTALLATION OF CHAMBER SECTION E 5 7 INSTALLATION OF CHAMBER SECTION F 5 8 INSTALLATION OF CHAMBER SECTION G Wiring Diagram 6 0 WIRING DIAGRAM Mai...

Page 4: ...t building plumbing and electrical skills An AlertMaxx2 EC High water level alarm DMS 599 is a recommended extra to alert the property occupant when the water level in the chamber becomes too high Please see section 1 4 for more details about optional extras designed for the Foul V3 pump station 1 1 TECHNICAL INFORMATION Pump Specification Pump Type D10SA Typical Duty I S Head m 3 8 30 4 7 50 5 6 ...

Page 5: ... DMS 129 6 Delta Foul V3 1 3 2 1 1 4 5 6 Part Description A Screed B Insulation C MS20 D Basement Slab E Inlet Pipe F Concrete Base G Manhole Cover H Foul V3 Chamber I Cable Duct J Discharge Pipe K Distribution Board L Non switched Fused Spur M Vent Pipe N AlertMaxx2 A B C D E F G H I J K L N M Membrane sealed to chamber with Delta 150mm corner strip 1 3 PARTS INCLUDED 1 4 OPTIONAL EXTRAS Chamber ...

Page 6: ...in DMS 0156 2 Socket Plain Plain DMS 0157 2 Socket BSP Female Thread BSP Female Thread DMS 339 2 Male Iron Plain BSP Male Thread DMS 0153 2 Male Iron Plain BSP Male Thread Non pressure DMS 335 110mm to 2 Adaptor DMS 341 Saddle Clamp 110mm to 2 BSP Female Thread including 2 Male Iron including 1 25 Male Iron DMS 0151 Saddle Clamp 160mm to 2 BSP Female Thread including 2 Male Iron including 1 25 Mal...

Page 7: ...Part No 1 2 Male Iron Non pressure DMS 335 2 2 Female 2 Male Adaptor DMS 337 3 2 Non Return Valve DMS 327 4 Foul V3 Discharge Bend DMS 334 5 D10SA Pump DMS 120 6 Discharge Arm c w DC65 Connector DMS 129 01992 523 523 info deltamembranes com www deltamembranes com 5 ...

Page 8: ...Technical on 01992 523 523 or pumps deltamembranes com to discuss chamber options 500mm 500mm The pump chamber must be installed no more than 500mm below floor finishes A pump chamber installed more than 500mm below floor finishes cannot be serviced safely in accordance with CDM regulations FOUL V3 INSTALLATION GUIDE X 6 ...

Page 9: ...station either during or after installation Please read these instructions carefully prior to installing the chamber If there is anything that is unclear please contact our technical help desk on 01992 523 523 4 1 PUMP STATION LOCATION This station requires routine maintenance therefore it is important that careful consideration is taken to position the chamber in a location that allows permanent ...

Page 10: ...e for chamber Refer to section 10 0 for RC box internal dimensions Install re bar as per structural engineer s drawings Lay inlet and discharge pipework Allow pipework to protrude into RC box by a minimum of 100mm Pour concrete to form RC box as per structural engineer s drawings FOUL V3 INSTALLATION GUIDE 8 1 2 3 4 ...

Page 11: ... Connecting 110mm inlet pipework Saw off socket end s where inlet pipe s are to be connected Position chamber in RC box Fit push fit coupler Connect inlet pipework to the required chamber spigot 01992 523 523 info deltamembranes com www deltamembranes com 9 5 6 7 8 ...

Page 12: ... the high pressure male iron into the socket Apply solvent cement around the first 20mm of the external face of the discharge cable duct and vent pipe and internal side of their respective male iron Push discharge cable duct and vent pipe into their respective male iron twisting the pipe as it is pushed into the male iron to remove any trapped air FOUL V3 INSTALLATION GUIDE 10 9 10 11 12 ...

Page 13: ...nstallation of Chamber Connecting discharge and cable duct Ensure a draw cord is pulled through the cable duct as the cable duct is built 01992 523 523 info deltamembranes com www deltamembranes com 13 11 ...

Page 14: ...d chamber with concrete To be followed when installing chamber in an RC box Check all pipes are connected to the chamber correctly Completely fill chamber with water Fill void between RC box and chamber with concrete min C35 grade or as per engineer s drawings FOUL V3 INSTALLATION GUIDE 12 14 15 16 ...

Page 15: ...with concrete To be followed when installing chamber in the ground Completely fill chamber with water Fill void between soil and chamber with concrete min C35 grade or as per engineer s drawings Allow concrete to cure 01992 523 523 info deltamembranes com www deltamembranes com 17 18 19 13 ...

Page 16: ...around chamber with concrete To be followed when installing chamber in the ground with a reinforced cage Completely fill chamber with water Fill void between soil and chamber with concrete min C35 grade or as per engineer s drawings Allow concrete to cure FOUL V3 INSTALLATION GUIDE 20 21 22 14 ...

Page 17: ...ON OF CHAMBER SECTION E Preparing chamber for installation of pump Pump out water from chamber Manually remove any debris from chamber and residual water using a wet vacuum 01992 523 523 info deltamembranes com www deltamembranes com 23 24 15 ...

Page 18: ...LLATION OF CHAMBER SECTION F REINFORCED CAGE Fitting discharge to pump Wrap the thread on the nipple glued in to the 90 bend with PTFE tape Hand tighten the discharge arm into the pump discharge outlet FOUL V3 INSTALLATION GUIDE 25 26 16 ...

Page 19: ...DC65 over the discharge arm and lower the pump in to chamber to release any trapped air Slide the DC65 up to join the manifold to the discharge arm Tighten the two screws on the DC65 to seal the pipework When installing a high level alarm refer to the AlertMaxx2 EC installation instructions 01992 523 523 info deltamembranes com www deltamembranes com 27 28 29 30 17 ...

Page 20: ...s supply and connect the pump and AlertMaxx2 EC according to the wiring diagram on page 19 Turn mains supply on and lift the pump float to test the water is discharging correctly To test float switch refer to the AlertMaxx2 EC installation instructions FOUL V3 INSTALLATION GUIDE 31 32 33 34 18 5 8 INSTALLATION OF CHAMBER SECTION G Installing pump in chamber and AlertMaxx2 EC ...

Page 21: ...with a 10m cable When only using the standard 10m cable attached to the pump the cable duct should be no longer than 6m If the cable duct requires to be longer than 6m please follow the cable extension guide to select an appropriate cable core diameter Pendant Float Switch Supplied with a 10m cable The electrical installation must comply with the requirements of BS 7671 2018 Requirements for Elect...

Page 22: ...e of writing due to there being no vaccine against leptospirosis weil s disease where rats may be present ensure appropriate personal protective equipment skin protection is worn and ensure any cuts or abrasions are fully covered There should be no eating or drinking during works and only afterwards following a change of clothing and washing Ensure electrical power to the pump is turned off isolat...

Page 23: ...ack into water lift float to activate pump before reconnecting the DC65 Discharge pipe is blocked a drainage company is required Pump is tripping Pump is wired incorrectly or not on a separate supply refer to section 6 0 wiring diagram High Level Alarm not functioning Refer to the high level alarm installation operating instructions In no event shall we be liable for any consequential damage penal...

Page 24: ... Delta Membrane Systems Ltd All Rights Reserved HEAD OFFICE Delta House Merlin Way North Weald Epping Essex CM16 6HR 01992 523 523 info deltamembranes com www deltamembranes com DMS_Foul_V3_Install_Guide_V3 ...

Reviews: