Series Temperature Controller 

Instruction Sheet 

Thank you very much for choosing Delta DTE series temperature controller. Please read this instruction sheet carefully before using your DTE 
to ensure proper operation. Keep this instruction sheet handy for quick reference. 

 Precaution 

 

DANGER! Caution! Electric Shock! 

DTE is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. 
The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for opening the 
enclosure) in case danger and damage on the device may occur

.

 

 WARNING! 

1. Prevent dust or metallic debris from falling into the device and cause malfunctions. DO NOT modify or uninstall the circuit board of DTE

without being permitted. DO NOT use empty terminals.

2. Keep away from high-voltage and high-frequency environment during the installation in case of interference. Prevent using the device in

premises which contain:
(a) dust or corrosive gas;    (b) high humidity and high radiation;    (c) shock and vibration.

3. The power has to be switched off when wiring or changing the temperature sensor.
4. When installing the circuit board of the accessory, please make sure the power of the main unit is switched off and insert the accessory

into the correct slot on the main unit.

5. Make sure to use compensation wire which matches the thermocouple or platinum resistance when extending or connecting the

thermocouple or platinum resistance.

6. Keep the wire as short as possible when wiring a sensor to the controller. Separate the power cable and load wire in order to prevent

interference and induced noise.

7. Make sure the power cables and signal device are installed correctly before switching on the power; otherwise serious damage may

occur.

8. DO NOT touch the terminal or repair the device when the power is on; otherwise an electric shock may occur.
9. Please wait for 1 minute after the power is switched off to allow the capacitor to discharge and DO NOT touch the internal wiring within

this period.

10. DO NOT touch the internal terminal when DTE is either switched on or off in case you may damage the circuit.
11. Please place DTE with other heating objects (e.g. power supply) within proper distance while installing DTE.

 Ordering Information 

Series name 

DTE: Delta E series temperature controller 

 1  

Device type 

1: main unit 

2: accessory 

 2   3

  -  

0T: 4-channel TC 
0P: 3-channel PT 

0T: 4-channel TC 
0V: 4 channels of voltage pulse output 
0C: 4 channels of linear current output 
0R: 4 channels of relay output 
0L: 4 channels of linear voltage output 
CT: 4 channels of current transformer sensors 
DS: Display and setup module 

0P: 3-channel PT 
0D: 8-channel EVENT input 

Call 1(800)985-6929 for Sales

deltaacdrives.com

[email protected]

Call 1(800)985-6929 for Sales

deltaacdrives.com

[email protected]

Summary of Contents for DTE10T Series

Page 1: ...the main unit 5 Make sure to use compensation wire which matches the thermocouple or platinum resistance when extending or connecting the thermocouple or platinum resistance 6 Keep the wire as short a...

Page 2: ...only applicable in the model with linear voltage and current output for OUT1 OUT2 Alarm modes 13 alarm modes available Communication RS 485 digital communication supports baudrate 2 400 to 115 200bps...

Page 3: ...hannels of input Every channel corresponds to 2 groups of output and 2 groups of alarms OUT1 and SUB1 are for control output and OUT1 can be used for proportional output OUT2 and SUB2 are fixed for al...

Page 4: ...larm output will be enabled when the PV is between SV AL H and SV AL L ON OFF AL L SV AL H 5 Alarm output will be enabled when the temperature reaches the absolute value of the upper and lower limits...

Page 5: ...ed Slot INA offers 4 channels of input and CH1 CH4 correspond to the current detected at CT1 CT4 Hardware requirement Accessory DTE2CT inserted in the slot AUX How to Operate 1 Enable the CT function...

Page 6: ...Bit0 Flag Hot runner control Slope control Latch CT EVENT Notes The flag to enable EVENT is at bit1 of 4824H Write 0002H to bit1 to set it on If the multistate function is enabled for example writing...

Page 7: ...ID latch function Write 1234H into the address 47F1H and then 0008H into address 4824H bits in 4824H Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Flag Hot runner control Slope control Latch CT EVENT Notes...

Page 8: ...the weighted average value of the current PV and previous PV The filter equation PV displayed value previous PV x filter times 1 current PV filter times The bigger the filter times the bigger the weig...

Page 9: ...006 H1700 H1007 H1800 Set temperature value Unit 0 1 H1008 H1101 H1009 H1201 H100A H1301 H100B H1401 H100C H1501 H100D H1601 H100E H1701 H100F H1801 Max temperature value Disabled when higher than def...

Page 10: ...B8 H1117 H10B9 H1217 H10BA H1317 H10BB H1417 H10BC H1517 H10BD H1617 H10BE H1717 H10BF H1817 Alarm 1 output mode See Alarm Output section H10C0 H1118 H10C1 H1218 H10C2 H1318 H10C3 H1418 H10C4 H1518 H1...

Page 11: ...of the current pattern 0 7 H1120 H1220 H1320 H1420 H1520 H1620 H1720 H1820 Read the NO of the current step 0 7 H1121 H1221 H1321 H1421 H1521 H1621 H1721 H1821 NO of start pattern 0 7 H1122 H1222 H132...

Page 12: ...content e g H01 H03 H10 H00 H00 H02 H16 Obtain 2 scomplement H EA RTU Mode Read Command Read Response Message Write Command Write Response Message Machine address H01 Machine address H01 Machine addre...

Page 13: ...l Size Connect maximum 7 DTC2000 or DTC2001 controllers to DTE by using DIN rail Call 1 800 985 6929 for Sales deltaacdrives com sales deltaacdrives com Call 1 800 985 6929 for Sales deltaacdrives com...

Reviews: