TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
24V 480W 1 Phase / DRP024V480W1AA
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (November 2020, Rev. 09)
5
EMC
Emission (CE & RE)
Generic Standards: CISPR 32, EN 55032, EN 55011, FCC
Title 47: Class B
Immunity
Generic Standards: EN 55024, EN 61000-6-2
Electrostatic Discharge
IEC 61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field
IEC 61000-4-3 Level 3 Criteria A
1)
80MHz-1GHz, 10V/M, 80% modulation (1kHz)
1.4GHz-2GHz, 3V/M, 80% modulation (1kHz)
2GHz-2.7GHz, 1V/M, 80% modulation (1kHz)
Electrical Fast Transient / Burst
IEC 61000-4-4 Level 3 Criteria A
1)
2kV
Surge
IEC 61000-4-5 Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
Conducted
IEC 61000-4-6 Level 3 Criteria A
1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields
IEC 61000-4-8 Criteria A
1)
100A/Meter
Voltage Dips and Interruptions
IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-12 Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
Harmonic Current Emission
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
Voltage Sag Immunity
SEMI F47 - 0706, at 100Vac
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)