background image

6

ASSEMBLY INSTRUCTIONS

NEW CONSTRUCTION – ATTACHING TO THE JOIST

BEFORE INSTALLATION

Turn off power source. Review all safety precautions.

1.  If spacing between joists is 12 in. apart, use four 

long wood screws (provided) to attach the fan body 

1

 to ceiling joists, NO NEED FOR SUSPENSION 

BRACKETS.

Hardware

A

 Long wood screw     

2.  For joist spacing 16 in.- 24 in., insert suspension 

bracket 

2

 into the bracket cover on the duct connector 

side and the back of the fan body 

1

.

Install the suspension brackets to the joists with long 

wood screw, and secure the suspension brackets to 
the fan body 

1

 by using the short screws (provided).

Hardware

A

 Long wood screw     

B

 Short screw              

Joist

1

A

Suspension Bracket

Fan Body

1

2

Joist

16"(406mm)

19.2"(487mm)

24"(609mm)

1

2

Summary of Contents for breez VFB160D6A3-DGL

Page 1: ...Instructions Existing Construction Grille Installation Operation Care and Maintenance Troubleshooting Dimensions Product Specifications Warranty 2 3 4 5 6 8 12 12 13 14 15 15 16 READ AND SAVE THESE IN...

Page 2: ...B PART DESCRIPTION QTY 1 Fan Body 1 2 Suspension bracket 4 3 6 to 4 adapter 1 4 Grille 1 HARDWARE CONTENTS Images are to scale 8 Long Wood Screw 4 x 25mm 4 Short Screw 8 32x1 4 PACKAGE CONTENTS 1 3 2...

Page 3: ...cient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and s...

Page 4: ...of your bath fan are not all included However most are available at your local home improvement or hardware store Proper insulation around the fan to minimize building heat loss and gain 6 circular du...

Page 5: ...wire firmly and push the stripped end of the wire into the open port of the connector Use only one conductor per port Verify the stripped end of the wires is fully inserted to the back of the connecto...

Page 6: ...R SUSPENSION BRACKETS Hardware A Long wood screw 2 For joist spacing 16 in 24 in insert suspension bracket 2 into the bracket cover on the duct connector side and the back of the fan body 1 Install th...

Page 7: ...ll be used for branch circuit wiring Reattach fan junction box cover c 4 Connect a 6 in circular duct a not supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied...

Page 8: ...ll safety precautions 1 Remove existing fan 2 Measure the opening to ensure it is large enough to accommodate the new fan body 10 1 4 in x 10 1 4 in 3 If this fan is not replacing an old fan be sure t...

Page 9: ...in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in Position the screws far enough away from the edge of the ceiling board that it does not crumble and give way Put screws in...

Page 10: ...ver c 8 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the wood support and 2 long wood screws through the flange int...

Page 11: ...using the short screws provided Hardware A Long wood screw B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring di...

Page 12: ...12 GRILLE INSTALLATION Attach grille 4 by pinching mounting springs a and insert into the narrow rectangular slots in fan body 4 a OPERATION Turn the POWER switch on to operate at full speed airflow...

Page 13: ...se resin parts in water over 140 Fahrenheit Turn off power source Review all safety precautions 1 To remove grille 4 squeeze springs and pull down 2 Clean the grille 4 in a sink and dry with a cloth 3...

Page 14: ...the size of your room 2 Check damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct close...

Page 15: ...1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Note VFB160D6A3 DGL 120 60 160 16 4 0 38 10 Single Speed Note Design and specifications subject to change without notice 11 21 32 295 8 6 150 7 7 8 2...

Page 16: ...onsequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product...

Reviews: