QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING:
Wiring must comply with all appliable electrical
codes. Turn OFF power before removing or installing
connectors.
WARNING:
COPPER TO COPPER ONLY. Do not use
aluminum wire.
CAUTION:
Accessory part (quick connector) should meet
installation instructions below.
NOTE:
The connector is reusable on solid wires of the
same wire gauge or smaller. Do not reuse the connector on
stranded wires.
• Strip wires 3/8 in. - 1/2 in.
•
Grip the wire firmly and push the stripped end of the
wire into the open port of the connector. Use only one
conductor per port.
• Verify the stripped end of the wires is fully inserted to the
back of the connector.
NOTE:
Important wire information. Maximum temperature
rating 221˚F (105˚C). 600 volts maximum for building wire
and 1,000 volts maximum for building wire and 1,000 volts
maximum in signs and lighting fixtures. The acceptable wire
range includes: Solid: 12-18 AWG.
WIRING DIAGRAM
OFF
ON
L
N
POWER SWITCH
JUNCTION BOX
SWITCH BOX
WHITE
BLACK
GREEN
GRD
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
Quick
connector
House
wires
Product
wires