background image

 

English

-

1

Preface 

This quick start will be helpful in the installation, wiring, inspection, and operation of Delta ASDA-A+ series AC 
servo drive and ECMA series servo motor. Before using the product, please read this quick start to ensure 
correct use. You should thoroughly understand all safety precautions before proceeding with the installation, 
wiring and operation. If you do not understand please contact your local Delta sales representative. Place this 
quick start in a safe location for future reference. Please observe the following precautions: 

„

  Do not use the product in a potentially explosive environment. 

„

  Install the product in a clean and dry location free from corrosive and inflammable gases or 

liquids. 

„

  Do not connect a commercial power supply to the U, V, W terminals of motor. Failure to observe 

this precaution will damage either the Servo motor or drive. 

„

  Ensure that the motor and drive are correctly connected to a ground. The grounding method must 

comply with the electrical standard of the country (Please refer to NFPA 70: National Electrical 
Code, 2005 Ed.). 

„

  Do not disconnect the AC servo drive and motor while the power is ON. 

„

  Do not attach, modify or remove wiring when power is applied to the AC servo drive and motor.   

„

  Before starting the operation with a mechanical system connected, make sure the emergency 

stop equipment can be energized and work at any time. 

„

  Do not touch the drive heat sink or the servo motor during operation. Otherwise, it may result in 

serious personnel injury. 

Further information on the AC servo drive and motor can be obtained from the manual. You can download the 
manual via the link http://www.delta.com.tw/industrialautomation/ above in PDF format. 

The content of this quick start may be revised without prior notice. Please consult our distributors or 
download the most updated version at http://www.delta.com.tw/industrialautomation/ . 

 

Safety Precautions 

Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating, 
maintaining and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark 
safety precautions when using the Delta’s servo product. Failure to observe these precautions may void the 
warranty! 
ASDA-A+ series drives are open type servo drives and must be installed in an NEMA enclosure such as a 
protection control panel during operation to comply with the requirements of the international safety standards. 
They are provided with precise feedback control and high-speed calculation function incorporating DSP 
(Digital Signal Processor) technology, and intended to drive three-phase permanent magnet synchronous 
motors (PMSM) to achieve precise positioning by means of accurate current output generated by IGBT 
(Insulated Gate Bipolar Transistor). 
ASDA-A+ series drives can be used in industrial applications and for installation in an end-use enclosure that 
do not exceed the specifications defined in the ASDA-A+ series user manual (Drives, cables and motors are 
for use in a suitable enclosure with a minimum of a UL50 type 1 or NEMA 250 Type 1 rating). 

Unpacking Check 

 

¾

 

Please ensure that both the servo drive and motor are correctly matched for size (power rating). 
Failure to observe this precaution may cause fire, seriously damage the drive / motor or cause 
personal injury. 

Installation 

 

¾

 

Do not install the product in a location that is outside the stated specification for the drive and motor. 
Failure to observe this caution may result in electric shock, fire, or personal injury. 

Summary of Contents for ASD-A4523-B

Page 1: ...5011666502 2008 11 20 APQ2...

Page 2: ...w industrialautomation above in PDF format The content of this quick start may be revised without prior notice Please consult our distributors or download the most updated version at http www delta co...

Page 3: ...form trial run with load connected After the servo motor is running normally and regularly without load then run servo motor with load connected Ensure to perform trial run in this order to prevent un...

Page 4: ...to corrosive gases and liquids Correctly packaged and placed on a solid surface Do not mount the servo drive or motor adjacent to heat radiating elements or in direct sunlight Do not mount the servo d...

Page 5: ...fan to increase ventilation to avoid ambient temperatures that exceed the specification When installing two or more drive adjacent to each other please follow the clearances as shown in the following...

Page 6: ...AWG8 3 3 AWG12 ECMA F21845 S 1 3 AWG16 3 3 AWG12 8 4 AWG8 3 3 AWG12 ASD A5523 B ECMA F21855 3 1 3 AWG16 3 3 AWG12 8 4 AWG8 3 3 AWG12 ASD A7523 B ECMA F21875 3 1 3 AWG16 3 3 AWG12 8 4 AWG8 3 3 AWG12 En...

Page 7: ...le materials inside the drive Never put inflammable objects on servo drive or close to the external regenerative resistor Make sure control switch is OFF If the electromagnetic brake is being used ens...

Page 8: ...e to the ring lug UL approved R C YDPU2 heat shrink tubing rated min 600Vac insulation shall be install over the live part of ring lug body in a minimum length specifies as the item E below More detai...

Page 9: ...English 8 Basic Wiring...

Page 10: ...English 9...

Page 11: ...3 0 6 6 NOTE 1 Dimensions are in millimeters and inches 2 Weights are in kilograms and pounds 3 In this quick start actual measured values are in metric units The units in imperial units are for refer...

Page 12: ...NOTE 1 Dimensions are in millimeters and inches 2 Weights are in kilograms and pounds 3 In this quick start actual measured values are in metric units The units in imperial units are for reference onl...

Page 13: ...NOTE 1 Dimensions are in millimeters and inches 2 Weights are in kilograms and pounds 3 In this quick start actual measured values are in metric units The units in imperial units are for reference onl...

Page 14: ...l Electrical Code 2005 Ed ASDA A ECMA http www delta com tw industrialautomation pdf http www delta com tw industrialautomation ASDA A open type Digital Signal Processor DSP IGBT PMSM ASDA A UL50 Type...

Page 15: ...2 10 30 11 8 PG 3 9 84 PG 20 65 62 10 CHARGE...

Page 16: ...3 20 C 65 C 4 F 149 F 0 90 4 5kW 5 5kW...

Page 17: ...m mm AWG L1 L2 R S T U V W P C ECMA F21830 S 1 3 AWG16 3 3 AWG12 3 3 AWG12 3 3 AWG12 ECMA E21835 S 1 3 AWG16 3 3 AWG12 3 3 AWG12 3 3 AWG12 ASD A4523 B ECMA F21845 S 1 3 AWG16 3 3 AWG12 8 4 AWG8 3 3 AW...

Page 18: ...5 mm AWG ASD A4523 B 0 13 AWG26 10 4 UL2464 3 9 84 ASD A5523 B 0 13 AWG26 10 4 UL2464 3 9 84 ASD A7523 B 0 13 AWG26 10 4 UL2464 3 9 84 NOTE 1 shielded twisted pair cable 2 SHIELD 3 10 OFF SERVO OFF LE...

Page 19: ...ZMVV D UL YDPU2 600V E D WIRE RANGE mm AWG F d2 W E U V W RNB22 10 22 mm2 4 AWG 6 0 6 0 12 20 17 32 R S T P D C RNB1 10 RNB2 6 RNB3 6 RNB5 7 4 6 mm2 10 18AWG 6 0 4 3 9 50 13 55 L1 L2 RNB1 10 RNB2 6 1...

Page 20: ...7...

Page 21: ...8...

Page 22: ...9 ASD A4523 B 4 5kW 3 0 6 6 NOTE 1 2 3...

Page 23: ...10 ASD A5523 B 5 5kW 5 5 12 1 NOTE 1 2 3...

Page 24: ...11 ASD A7523 B 7 5kW 8 0 17 6 NOTE 1 2 3...

Page 25: ...12...

Page 26: ...l Electrical Code 2005 Ed ASDA A ECMA http www delta com tw industrialautomation pdf http www delta com tw industrialautomation ASDA A open type Digital Signal Processor DSP IGBT PMSM ASDA A UL50 Type...

Page 27: ...2 10 30 11 8 PG 3 9 84 PG 20 65 62 10 CHARGE...

Page 28: ...3 20 C 65 C 4 F 149 F 0 90 4 5kW 5 5kW...

Page 29: ...m mm AWG L1 L2 R S T U V W P C ECMA F21830 S 1 3 AWG16 3 3 AWG12 3 3 AWG12 3 3 AWG12 ECMA E21835 S 1 3 AWG16 3 3 AWG12 3 3 AWG12 3 3 AWG12 ASD A4523 B ECMA F21845 S 1 3 AWG16 3 3 AWG12 8 4 AWG8 3 3 AW...

Page 30: ...5 mm AWG ASD A4523 B 0 13 AWG26 10 4 UL2464 3 9 84 ASD A5523 B 0 13 AWG26 10 4 UL2464 3 9 84 ASD A7523 B 0 13 AWG26 10 4 UL2464 3 9 84 NOTE 1 shielded twisted pair cable 2 SHIELD 3 10 OFF SERVO OFF LE...

Page 31: ...ZMVV D UL YDPU2 600V E D WIRE RANGE mm AWG F d2 W E U V W RNB22 10 22 mm2 4 AWG 6 0 6 0 12 20 17 32 R S T P D C RNB1 10 RNB2 6 RNB3 6 RNB5 7 4 6 mm2 10 18AWG 6 0 4 3 9 50 13 55 L1 L2 RNB1 10 RNB2 6 1...

Page 32: ...7...

Page 33: ...8...

Page 34: ...9 ASD A4523 B 4 5kW 3 0 6 6 NOTE 1 2 3...

Page 35: ...10 ASD A5523 B 5 5kW 5 5 12 1 NOTE 1 2 3...

Page 36: ...11 ASD A7523 B 7 5kW 8 0 17 6 NOTE 1 2 3...

Page 37: ...12...

Reviews: