  External Control Mode 

The external control mode exercises control through communication. The following shows the I/O signal 

contacts.

 

USB 

USB 

Power 

I/O Output (D-Sub 15Pin Female) 

I/O Input (D-Sub 15Pin Male) 

RS485 (D-Sub 9Pin) 

RJ45 (Network port) 

Summary of Contents for AM-ESP-S005 Series

Page 1: ...www deltaww com Delta Servo Press S Series Installation and Maintenance Instructions...

Page 2: ...eight of the Whole Machine 10 4 2 Repair 11 4 2 1 AM ESP S005 XXXX AM ESP S010 XXXX Standard Type 11 4 2 2 AM ESP S030 XXXX AM ESP S050 XXXX Standard Type 12 4 3 Standard Stand alone Model Working Pla...

Page 3: ...press or power lines get exposed to water or oil Make sure that the power line is properly plugged and fastened The emergency stop button needs to be kept clear of concealment by surrounding items Ma...

Page 4: ...the emergency stop button right away and notify the Company Delta Electronics or the contract service provider 1 3 Safety Information During Maintenance and Under Other Circumstances Item Description...

Page 5: ...is is a two hand press button controlled operation model To apply this operation mode one has to press and hold two operation buttons at the same time for activation purpose The operation buttons are...

Page 6: ...uzzer will sound In addition a warning message appears on the human machine interface or teaching box To reset the emergency stop state simply turn the pressed emergency stop button clockwise The figu...

Page 7: ...nance Instructions 6 2 3 External Control Mode The external control mode exercises control through communication The following shows the I O signal contacts USB USB Power I O Output D Sub 15Pin Female...

Page 8: ...ns 7 Input pins Pin Definition Pin Definition 1 24V Input 9 Recipe 3 2 On 10 3 Trigger 11 4 Alarm Reset 12 5 Safety Signal 13 6 Recipe 0 14 7 Recipe 1 15 8 Recipe 2 Output pins Pin Definition Pin Defi...

Page 9: ...Delta Electronics Servo Press S Series Installation and Maintenance Instructions 8 RS485 pins Pin Definition 1 RS485 D 2 RS485 D 3 FG 4 5 6 7 8 9...

Page 10: ...following figure uses the AM ESP S010 XXXX as an example Side view Front view Safety light curtain This item is to be prepared or purchased optionally by the RS 485 or RJ 45 connector This item is to...

Page 11: ...shown in the Quick Start Guide before taking out the hanging strap and inserting it into the corresponding lock hole Please make sure to lock the strap firmly When the servo press is being transporte...

Page 12: ...fastening ports for attaching the servo press are shown in the figure below Please use 4 general M10X1 5 hex screws JIS strength 12 9 length 45 and apply the tightening torque of 663 kgf cm Caution Pl...

Page 13: ...ing ports for attaching the servo press are shown in the figure below Please use 4 general M20X2 5 hex screws JIS strength 12 9 length 80 and apply the tightening torque of 5600 kgf cm Caution Please...

Page 14: ...ries Installation and Maintenance Instructions 13 4 3 Standard Stand alone Model Working Platform 4 3 1 AM ESP S005 XXXX AM ESP S010 XXXX Standard Type Please produce the processing jig according to t...

Page 15: ...tronics Servo Press S Series Installation and Maintenance Instructions 14 4 3 2 AM ESP S030 XXXX AM ESP S050 XXXX Standard Type Please produce the processing jig according to the dimensions shown in t...

Page 16: ...n of the spindle is shown below For the punch jig please use M8 x 1 25 length 8mm set screws Caution The top of the spindle punch is installed with the load cell Do not assemble tools in a way that co...

Page 17: ...lation and Maintenance Instructions 16 4 4 2 AM ESP S030 XXXX AM ESP S050 XXXX Standard Type The cross section of the spindle is shown below For the punch jig please use M5 x 0 8 length 12mm hex screw...

Page 18: ...signs are provided in the preceding three sections Extended descriptions and precautions are provided hereunder See the table below Item Description Jig weight Payload For the weight limits please fol...

Page 19: ...ish the oil through the inlet shown in the figure Regular oil replenishment is required to prevent shortening the machine s working life It is recommended to use NSK LR3 Recommended oil injector KCG 4...

Page 20: ...r basis after the warranty period expires The load cell calibration tool is shown in the figure Please follow the Operating Instructions while performing calibration and qualification or contact the C...

Page 21: ...EL 55 12 3932 2300 FAX 55 12 3932 237 Mexico Delta Electronics International Mexico S A de C V Gustavo Baz No 309 Edificio E PB 103 Colonia La Loma CP 54060 Tlalnepantla Estado de M xico TEL 52 55 360...

Reviews: