15.0 LED codes
14
For technical support, please call 01279 757400
AlertMaxx
Beep
Red LED
Blue LED
Green LED
Fault
1/sec
3/sec
High water alarm
1/min
1/5sec
1/sec
Mains failure
Any
Solid
Any
Error - Call support
1/min
Any
1/sec
Any
Service required
2/sec
High water has occurred
1/sec
All OK
All flash in sequence
Battery too low to start up
Various
Solid
Serious internal error
3/sec
Solid
Float cable issues
16.0 Troubleshooting
Fault
Cause
The unit does not turn on.
Battery is flat - charge the battery by connecting
mains supply to alarm unit.
Still doesn’t turn on after 3 mins - alarm unit is
faulty.
The LEDs flash in the following order, red, blue,
green.
Low battery - charge the battery by connecting
mains supply to alarm unit.
The red LED is flashing and the blue LED is solid.
Float switch cable is faulty - check float switch
connections and cable for damage.
Float switch is broken - replace float switch.
Float cable is broken - replace float switch.
The alarm does not activate when the float switch
is lifted.
The alarm does not activate when pressing the
‘TEST’ button
Faulty unit.
Alarm continuously active.
Float has been incorrectly wired - check the cables
are connected correctly.
Finger float has been installed upside down.