background image

Copyright 2013 Delta Scientific Corporation 

Page 16 of 17 

All Rights Reserved 

Document A2021.6 

i) 

If  Gate  functions  on  ‘Manual’  but  does  not  respond  to  vend  or  reset  signals; 
check  control  devices  and  detectors.  When  possible,  exchange  known  good 
components for suspected ones. 

 
ii) 

If control devices and detectors are proved OK, the field wiring or harnesses are 
to be suspected. Call factory for help. 

 
B. 

If Gate runs but cycles up and down without stopping: 
 
i) 

Check limit switch adjustment per the above instructions. 

 
ii) 

If the limit switches are in their proper location, at least one switch is likely failed. 
If  the  Gate  runs  on  with  the  'AUTO-MANUAL'  switch  in  the  ‘MANUAL’  position 
the  UP  limit  switch  has  failed.  If  the  Gate  runs  on  in  the  ‘Auto’  position  the 
DOWN limit switch is failed. 

 
If gate moves erratically: 
 
Erratic gate motion requires the drive belt tension to be checked. Open the AG812’s door and 
inspect the drive belt for looseness or excessive wear. If the belt appears worn or frayed, or if 
the belt appears loose, first: remove Electrical Power to the gate and second, tighten or replace 
the belt with a new one. To remove or tighten the belt, first loosen the Electrical Motor mounting 
nuts slightly and pull the motor away from the Gear Reducer, then tighten the Electrical, motor 
mounting nuts, thus tightening the drive belt. 
 
Power Loss 
 
The Delta AG812 can be opened or closed in the event of a power outage by the following: 
 

CAUTION:  Power  switch  should  be  in  the  ‘Off’  position  when  manually  operating  the 
gate to prevent hands from being caught in the drive belt pulleys if motor should happen 
to start if power is restored. 

 
1. 

Manually  pull  the  drive  belt  around  until  the  gate  is  in  the  desired  position.  Use  Care! 
Drive belt-pulley is a pinch point! 

 
2. 

Turn  Auto-Manual  switch  to  ‘AUTO’  and  the  Power  switch  to  ‘ON’.  On  power 
resumption, the Gate will automatically resume powered operation. 

Summary of Contents for AG812

Page 1: ...ODEL AG812 ACCESS GATE WARRANTY INSTALLATION OPERATION CORPORATE HEADQUARTERS 40355 Delta Lane Palmdale California 93551 Phone 661 575 1100 Fax 661 575 1109 Email info deltascientific com EASTERN REGI...

Page 2: ...ISCLAIMER Please note careful consideration must be devoted to the selection placement and design of a Barricade installation Just as in the case of any Barricade system perimeter security device or s...

Page 3: ...MANUAL GATE ARM OPERATION OPTION 6 DRIVE BELT TENSION 6 SPARE PARTS ORDER DATA 7 DART ARM OPTION 7 HOOK UP SCHEMATICS 2 Lane Single Direction Cash In Or Out 8 2 Lane Cash Entry Free Exit 9 1 Lane Coi...

Page 4: ...These devices may be used independently or in combination In short any device which can provide a contact closure may be used to vend or reset the Gate Safety The Model AG812 Access Gate is equipped w...

Page 5: ...ox breather vent and remove plug Vent hole faces upwards when the box is in operation 8 Install Gate Arm Wiring As indicated above the Gate will function using a wide variety of control inputs Consult...

Page 6: ...loosen the thumbscrew on the up limit switch cam and rotate slightly CCW Confirm as above 4 To adjust the gate arm for less upward travel loosen the thumbscrew on the up limit switch cam and rotate s...

Page 7: ...c For control circuits list model number serial number S N drawing number and customer number taken from the nameplate on the controller Dart Arm optional The dart arm is an optional factory installed...

Page 8: ...Copyright 2013 Delta Scientific Corporation Page 8 of 17 All Rights Reserved Document A2021 6...

Page 9: ...Copyright 2013 Delta Scientific Corporation Page 9 of 17 All Rights Reserved Document A2021 6...

Page 10: ...Copyright 2013 Delta Scientific Corporation Page 10 of 17 All Rights Reserved Document A2021 6...

Page 11: ...Copyright 2013 Delta Scientific Corporation Page 11 of 17 All Rights Reserved Document A2021 6...

Page 12: ...Copyright 2013 Delta Scientific Corporation Page 12 of 17 All Rights Reserved Document A2021 6...

Page 13: ...Copyright 2013 Delta Scientific Corporation Page 13 of 17 All Rights Reserved Document A2021 6...

Page 14: ...Copyright 2013 Delta Scientific Corporation Page 14 of 17 All Rights Reserved Document A2021 6...

Page 15: ...ly by draining old oil and refilling with clean Texaco Vanguard oil or equivalent 2 Tighten all nuts bolts and screws on the Gate assembly every 60 days or as necessary 3 Wash and wax the Gate cabinet...

Page 16: ...e belt tension to be checked Open the AG812 s door and inspect the drive belt for looseness or excessive wear If the belt appears worn or frayed or if the belt appears loose first remove Electrical Po...

Page 17: ...T ASSEMBLY 4369 11 BEARING PLATE with BUSHING FOR AG812 4369 12 SHAFT COLLAR 1 25 BORE 4369 13 ARM HOLDER 4369 14 ARM HOLDER RETAINING PLATE 4369 15 CONNECTING ARM with BUSHING 4369 16 GEAR BOX MOUNTI...

Page 18: ......

Page 19: ...PLATE 4369 14 15 1 CONNECTING ARM WITH BUSHINGS 4369 15 15A 1 DART CONNECTING ARM ASSY OPTION 5 7 5 7 3312 00 16 1 GEAR BOX MOUNTING PLATE 4369 16 17 1 MOTOR MOUNTING PLATE 4369 17 18 2 LIMIT SWITCH...

Page 20: ...F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MODEL C 24 B1 BRIDGE DIODE 1A 50V DIGI KEY DB 101NP C1 CAPACITOR 1000 mF 35V C2 CAPACITOR 330 mF...

Page 21: ......

Page 22: ...R 330 OHM 1 2W U1 U2 OPTO ISOLATOR MOTOROLA MOC3041 CA CAMDEN TERMINAL STRIP FEMALE CTB 7300 24F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MO...

Page 23: ......

Reviews: