background image

Copyright 2013 Delta Scientific Corporation 

Page 2 of 17 

All Rights Reserved 

Document A2021.6 

WARRANTY AND LIMITATION OF LIABILITY

 

 
Delta Scientific Corporation warrants that during the first ninety (90) days from date of shipment, 
the Products will be free from defect in material and workmanship. Delta's sole obligation under 
this  warranty  shall  be  to  repair  (or  at  Delta's  option,  to  replace),  FOB:  Palmdale,  California,  any 
defective product, without charge to Buyer, provided that, (a) Buyer gives Delta written notice of 
any such claimed defect within such period of ninety (90) days, (b) the Products, if installed, were 
installed  by  a  Delta  authorized  installer,  (c)  the  Products  have  not  been  altered,  subjected  to 
misuse, negligence or accident, or used with parts not authorized by Delta, and (d) the Products 
have been maintained in accordance with the instructions provided. NO OTHER WARRANTY IS 
EXPRESSED  AND  NONE  SHALL  BE  IMPLIED,  INCLUDING  WITHOUT  LIMITATION  THE 
WARRANTY  OF  MERCHANTABILITY  OR  WARRANTY  OF  FITNESS  FOR  USE  OR  FOR  A 
PARTICULAR  PURPOSE.  THE  FOREGOING  STATES  DELTA'S  ENTIRE  LIABILITY  WITH 
RESPECT TO THE PRODUCTS. IN NO EVENT SHALL DELTA BE LIABLE FOR ANY SPECIAL, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH RESULT FROM THE USE BY BUYER 
OR  ANY  OTHER  PARTY,  OF  THE  PRODUCTS,  AND  IN  NO  EVENT  SHALL  DELTA'S 
LIABILITY EXCEED THE AMOUNTS PAID BY BUYER FOR THE PRODUCTS HEREUNDER. 
 

DISCLAIMER

 

 
Please note - careful consideration must be devoted to the selection, placement and design of a 
Barricade  installation.  Just  as  in  the  case  of  any  Barricade  system, perimeter security device or 
security  gate  that  blocks  a  roadway  or  drive,  care  must  be  taken  to  ensure  that  approaching 
vehicles  as  well  as  pedestrians  are  fully  aware  of  the  Barricades  and  their  operation.  Proper 
illumination,  clearly  worded  warning  signs,  auxiliary  devices  such  as  semaphore  gates,  stop-go 
signal  lights,  audible  warning  devices,  speed  bumps,  flashing  lights,  beacons,  etc.  should  be 
considered.  Delta  has  information  available  on  many  such  auxiliary  safety  equipment  not 
specifically listed herein. It is strongly recommended that an architect and/or a traffic and/or safety 
engineer  be  consulted  prior  to  installation  of  a  Barricade  system.  Delta  will  offer  all  possible 
assistance in designing the operating equipment, controls and the overall system, but we are not 
qualified, nor do we purport to offer either traffic or safety engineering information. 
 

INTELLECTUAL PROPERTY, DRAWINGS, SPECIFICATIONS AND TECHNICAL DATA

 

 
The  drawings  and/or  data  included  with  this  equipment  unless  otherwise  noted  remain  the 
confidential property and trade secret of Delta Scientific Corporation. They shall not be disclosed, 
reproduced or used for manufacture, design or construction without the express authorization of 
Delta  Scientific  Corporation.  The  recipient  by  accepting  these  drawings  and/or  data,  assumes 
custody  thereof  and  under  the  above  terms  agrees  not  to  allow  the  use  of  by  unauthorized 
persons. 

Summary of Contents for AG812

Page 1: ...ODEL AG812 ACCESS GATE WARRANTY INSTALLATION OPERATION CORPORATE HEADQUARTERS 40355 Delta Lane Palmdale California 93551 Phone 661 575 1100 Fax 661 575 1109 Email info deltascientific com EASTERN REGI...

Page 2: ...ISCLAIMER Please note careful consideration must be devoted to the selection placement and design of a Barricade installation Just as in the case of any Barricade system perimeter security device or s...

Page 3: ...MANUAL GATE ARM OPERATION OPTION 6 DRIVE BELT TENSION 6 SPARE PARTS ORDER DATA 7 DART ARM OPTION 7 HOOK UP SCHEMATICS 2 Lane Single Direction Cash In Or Out 8 2 Lane Cash Entry Free Exit 9 1 Lane Coi...

Page 4: ...These devices may be used independently or in combination In short any device which can provide a contact closure may be used to vend or reset the Gate Safety The Model AG812 Access Gate is equipped w...

Page 5: ...ox breather vent and remove plug Vent hole faces upwards when the box is in operation 8 Install Gate Arm Wiring As indicated above the Gate will function using a wide variety of control inputs Consult...

Page 6: ...loosen the thumbscrew on the up limit switch cam and rotate slightly CCW Confirm as above 4 To adjust the gate arm for less upward travel loosen the thumbscrew on the up limit switch cam and rotate s...

Page 7: ...c For control circuits list model number serial number S N drawing number and customer number taken from the nameplate on the controller Dart Arm optional The dart arm is an optional factory installed...

Page 8: ...Copyright 2013 Delta Scientific Corporation Page 8 of 17 All Rights Reserved Document A2021 6...

Page 9: ...Copyright 2013 Delta Scientific Corporation Page 9 of 17 All Rights Reserved Document A2021 6...

Page 10: ...Copyright 2013 Delta Scientific Corporation Page 10 of 17 All Rights Reserved Document A2021 6...

Page 11: ...Copyright 2013 Delta Scientific Corporation Page 11 of 17 All Rights Reserved Document A2021 6...

Page 12: ...Copyright 2013 Delta Scientific Corporation Page 12 of 17 All Rights Reserved Document A2021 6...

Page 13: ...Copyright 2013 Delta Scientific Corporation Page 13 of 17 All Rights Reserved Document A2021 6...

Page 14: ...Copyright 2013 Delta Scientific Corporation Page 14 of 17 All Rights Reserved Document A2021 6...

Page 15: ...ly by draining old oil and refilling with clean Texaco Vanguard oil or equivalent 2 Tighten all nuts bolts and screws on the Gate assembly every 60 days or as necessary 3 Wash and wax the Gate cabinet...

Page 16: ...e belt tension to be checked Open the AG812 s door and inspect the drive belt for looseness or excessive wear If the belt appears worn or frayed or if the belt appears loose first remove Electrical Po...

Page 17: ...T ASSEMBLY 4369 11 BEARING PLATE with BUSHING FOR AG812 4369 12 SHAFT COLLAR 1 25 BORE 4369 13 ARM HOLDER 4369 14 ARM HOLDER RETAINING PLATE 4369 15 CONNECTING ARM with BUSHING 4369 16 GEAR BOX MOUNTI...

Page 18: ......

Page 19: ...PLATE 4369 14 15 1 CONNECTING ARM WITH BUSHINGS 4369 15 15A 1 DART CONNECTING ARM ASSY OPTION 5 7 5 7 3312 00 16 1 GEAR BOX MOUNTING PLATE 4369 16 17 1 MOTOR MOUNTING PLATE 4369 17 18 2 LIMIT SWITCH...

Page 20: ...F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MODEL C 24 B1 BRIDGE DIODE 1A 50V DIGI KEY DB 101NP C1 CAPACITOR 1000 mF 35V C2 CAPACITOR 330 mF...

Page 21: ......

Page 22: ...R 330 OHM 1 2W U1 U2 OPTO ISOLATOR MOTOROLA MOC3041 CA CAMDEN TERMINAL STRIP FEMALE CTB 7300 24F MALE CTB 7300 24F L CAMDEN TERMINAL STRIP FEMALE CTB 7300 12F MALE CTB 7300 12F STAT THERMOSTAT PEPI MO...

Page 23: ......

Reviews: