background image

Delta Faucet Canada, a division of Masco Canada Limited

350 South Edgeware Road, St. Thomas, Ontario, N5P 4L1

1-800-567-3300 (English)    1-800-265-9245 (French)

Delta Faucet Company

Box 40980, 55 East 111th St., Indianapolis, IN, U.S.A. 46280

(317) 848-1812

www.deltacommercialfaucets.com

Page 8

212294   Rev. 

B

Delta

®

 Commercial Faucet Limited Warranty

All parts of Delta® HDF® and TECK® faucets are warranted to the original commercial purchaser to be free from defects in material, finish and workmanship for a period of five (5) 

years unless otherwise specifically stated in the catalogue and price book. This warranty is made to the original commercial purchaser and shall be effective from date of purchase 

as shown on the purchaser’s receipt.
Delta Faucet will, at its option, repair or replace, FREE OF CHARGE, during the warranty period, any part which proves defective in material or workmanship under normal installa-

tion, use and water and service conditions. If Delta Faucet concludes that the returned part was manufactured by Delta Faucet and is, in fact, defective, then Delta Faucet will honor 

the warranty stated herein. Replacement parts can be obtained from your local dealer or distributor listed in the telephone directory or by returning the part along with the 

purchaser’s receipt to our factory, TRANSPORTATION CHARGES PREPAID, at the address listed. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY MADE BY DELTA FAUCET. ANY 

CLAIMS MADE UNDER THIS WARRANTY MUST BE MADE DURING THE FIVE-YEAR PERIOD REFERRED TO ABOVE. ANY IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF 

MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LABOUR CHARGES AND/OR DAMAGE INCURRED 

IN INSTALLATION, REPAIR OR REPLACEMENT AS WELL AS INCIDENTAL AND CONSEQUENTIAL, SPECIAL, INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED 

AND WILL NOT BE PAID BY DELTA FAUCET.
Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above 

limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state/province to state/province. 
This warranty is for commercial products only from Delta Faucet Company and Delta Faucet Canada (a division of Masco Canada Limited) and is void for any damage to this faucet 

due to misuse, abuse, neglect, accident, improper installation, or any use in violation of instructions furnished by Delta Faucet.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warning: Changes or modifications not expressly approved by Delta could void the user’s authority to operate the equipment.
CAN ICES-3 (A) / NMB-3(A)

© 201

8

 Masco Canada Ltd.

For further technical assistance, call Delta Commercial Technical Service at 

1-800-387-8277 

(Canada) or 

1-877-509-2680 

(U.S.A.).

Summary of Contents for 591T Series

Page 1: ... L min 061203A Vandal Resistant Laminar Outlet with Wrench 0 5 GPM 1 9 L min 061176A Vandal Resistant Laminar Outlet with Wrench 1 0 GPM 3 8 L min 061104A Vandal Resistant Flow Control Non Aerating Spray Outlet with Wrench 0 35 USGPM 1 3 L min RP31704 Optional Vandal Resistant Spray Outlet with Wrench 0 5 GPM 1 9 L min 060566A Optional Vandal Resistant Spray Outlet with Wrench 1 0 GPM 3 8 L min RP...

Page 2: ...tly inside the battery box Do not remove battery snap from hardwire converter by using a flat screwdriver damage may result Turn on power supply for the transformer STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects from the sink STEP 7 TIE SPOUT CABLE Attach spout cable to box connector Use tie wraps to secure spout cable to spout hose Your faucet ...

Page 3: ...asin to minimize sensor cord exposure Rough in drainage Rough in water supply to 10 control box inlets and to spout connection Finish walls Valve spacer is for temporary use only for flushing of system Must be replaced with solenoid valve and washers Fig 6 7 Clean deck sink surface where faucet will be mounted Mount faucet to sink using nut s and washer s provided Fig 1 Installation of the deck ga...

Page 4: ...the temperature is more than 3 F from the commissioning in temperature refer to the included Cash Acme Maintenance and Installation Guide 4D Close stop s STEP 5 CONNECT ELECTRICAL SUPPLY SOLENOID VALVE AND SENSOR Remove plastic threaded spacer nipple and install solenoid valve with body arrow in the direction of water flow See Fig 10 Feed sensor wire from spout into control box and then connect to...

Page 5: ...to 15 from sensor 5 7 10 12 15 30 45 60 75 90 seconds 2 0 4 0 6 0 8 0 9 9 minutes Symbol d T R Rinse Cycle If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the faucet to stay on to move the water in the line if the Rinse Cycle is made active 10 seconds onc...

Page 6: ...e default setting is OFF METERING MODE M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected and will continue to run after the user removes their hands Options are OFF 7 8 9 10 11 12 13 14 15 18 24 30 40 50 60 90 seconds and 2 0 2 5 3 0 3 5 4 0 minutes decimal denotes minutes The default setting is OFF Note Auto...

Page 7: ...ce Hard Wire converter 060683A if required The faucet stops working No water flow Check the function of the solenoid Step 3 The solenoid should click when activated Clean as required Correct as required If there is a clicking sound If no clicking sound This indicates that both the sensor and the solenoid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming ...

Page 8: ...NTIAL SPECIAL INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT BE PAID BY DELTA FAUCET Some states provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have othe...