background image

Page 5

212294   Rev. 

B

FOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8

STEP 7. TEST FOR OPERATION

Test for operation.  If unit does not work properly, see Troubleshooting Guide on page 7.

STEP 8. MAKING ADJUSTMENTS

If adjustments are required.  Note factory defaults for program shown in Quick Reference Chart. Otherwise, replace the driver 

board housing cover as the electronic product is ready for use.

INSTALLATION AND SET UP INSTRUCTIONS

w w w . s p e c s e l e c t . c o m

DRIVER BOARD QUICK REFERENCE CHART

Function

Description

Factory

Default Setting

Function Settings

Sensor Range

Auto Timer

(faucet shut-off)

You can set the distance at which the sensor will detect hands

in the wash area.

A safety mode in the event the sensor continually sees a target.

9” from sensor

45 seconds

3” to 15” from sensor

5, 7, 10, 12, 15, 30, 45, 60, 75, 90

seconds

2.0, 4.0, 6.0, 8.0, 9.9 minutes

Symbol

d

T

R

Rinse Cycle

If this feature is turned to an “xx” hour value, the faucet will turn

on itself after this set time from last use.

- (OFF), 6, 12, 18, 24, 30, 36,

42, 48 hours

r

Rinse Time

This is the amount of time you want the faucet to stay on to move

the water in the line, if the 

Rinse Cycle

 is made active.

10 seconds

(once enabled)

10, 20, 30, 40, 50, 60, 90 seconds

2.0, 2.5, 3.0 minutes

Metering Mode

b

Buzzer

Buzzer will annunciate twice upon power up indicating product is

ready to use.

ON

ON, - (OFF)

L

LED

LED will light up indicating low power.

- (OFF)

ON, - (OFF)

M

This feature changes the product into a metering faucet; it will run

the full set amount of time after the user’s hands are first detected.

-- (OFF), 7, 8, 9, 10, 11, 12, 13,

14, 15, 18, 24, 30, 40, 50, 60, 90

seconds

2.0, 2.5, 3.0, 3.5, 4.0 minutes

- (OFF)

- (OFF)

MAXIMUM LIP HEIGHT FOR DECK MOUNTED SINKS

For sensor clearance:

10 mm (0.4”) maximum sink 

lip height from deck

Summary of Contents for 591T Series

Page 1: ... L min 061203A Vandal Resistant Laminar Outlet with Wrench 0 5 GPM 1 9 L min 061176A Vandal Resistant Laminar Outlet with Wrench 1 0 GPM 3 8 L min 061104A Vandal Resistant Flow Control Non Aerating Spray Outlet with Wrench 0 35 USGPM 1 3 L min RP31704 Optional Vandal Resistant Spray Outlet with Wrench 0 5 GPM 1 9 L min 060566A Optional Vandal Resistant Spray Outlet with Wrench 1 0 GPM 3 8 L min RP...

Page 2: ...tly inside the battery box Do not remove battery snap from hardwire converter by using a flat screwdriver damage may result Turn on power supply for the transformer STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects from the sink STEP 7 TIE SPOUT CABLE Attach spout cable to box connector Use tie wraps to secure spout cable to spout hose Your faucet ...

Page 3: ...asin to minimize sensor cord exposure Rough in drainage Rough in water supply to 10 control box inlets and to spout connection Finish walls Valve spacer is for temporary use only for flushing of system Must be replaced with solenoid valve and washers Fig 6 7 Clean deck sink surface where faucet will be mounted Mount faucet to sink using nut s and washer s provided Fig 1 Installation of the deck ga...

Page 4: ...the temperature is more than 3 F from the commissioning in temperature refer to the included Cash Acme Maintenance and Installation Guide 4D Close stop s STEP 5 CONNECT ELECTRICAL SUPPLY SOLENOID VALVE AND SENSOR Remove plastic threaded spacer nipple and install solenoid valve with body arrow in the direction of water flow See Fig 10 Feed sensor wire from spout into control box and then connect to...

Page 5: ...to 15 from sensor 5 7 10 12 15 30 45 60 75 90 seconds 2 0 4 0 6 0 8 0 9 9 minutes Symbol d T R Rinse Cycle If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the faucet to stay on to move the water in the line if the Rinse Cycle is made active 10 seconds onc...

Page 6: ...e default setting is OFF METERING MODE M This feature changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected and will continue to run after the user removes their hands Options are OFF 7 8 9 10 11 12 13 14 15 18 24 30 40 50 60 90 seconds and 2 0 2 5 3 0 3 5 4 0 minutes decimal denotes minutes The default setting is OFF Note Auto...

Page 7: ...ce Hard Wire converter 060683A if required The faucet stops working No water flow Check the function of the solenoid Step 3 The solenoid should click when activated Clean as required Correct as required If there is a clicking sound If no clicking sound This indicates that both the sensor and the solenoid are functioning Ensure inlet screen on solenoid is not plugged with debris Check the incoming ...

Page 8: ...NTIAL SPECIAL INDIRECT OR PUNITIVE DAMAGES CONNECTED THEREWITH ARE EXCLUDED AND WILL NOT BE PAID BY DELTA FAUCET Some states provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have othe...

Reviews: