Page 5
209491 Rev. B
STEP 7. TEST FOR OPERATION
Test for operation. If unit does not work properly, see Troubleshooting Guide on page 7.
STEP 8. MAKING ADJUSTMENTS
If adjustments are required. Note factory defaults for program shown in Quick Reference Chart.
Otherwise, replace the driver board housing cover as the electronic product is ready for use.
Minimum Recommended
Distance 9" (229mm)
1"
(25mm)
Operation
Illustration
Adjustment Range
Factory Default Setting
Description
Selection Adjustment
0 to 8 seconds and
then 1 minute to 8
minutes
0 Seconds
The length of time water will run after
the user removes their hands from the
sensing zone.
Run-On time
3 Settings:
Fast (8 pulses/second)
Standard (4 pulses/second)
Slow (2 pulses/second)
Standard (4 pulses/second)
Response Time is the amount of time it
takes for the sensor to react to hands
placed in the sensing zone.
Response Time
1 to 8 seconds of
blocking time
1 second
The amount of time required between
uses. This prevents the faucet from
running water excessively.
Block Time
3” to 15” from sensor
10” from sensor
You can set the distance at which the
sensor will detect hands in the wash area.
Sensor Range
Not Adjustable
1 Run-On time
The auto timer is the length of time
before the faucet stops running in the
event that the sensor is obstructed by
a foreign object.
Auto Timer
7 to 240 seconds
(if enabled)
Disabled
Allows for continuous flow for a set amount
of time, regardless of how long an object
is placed in front of the sensor. Run-On
settings are disabled in this mode.
Metering Mode
3000TA CONTROLLER QUICK REFERENCE CHART
UP and DOWN arrows
These arrows are used to navigate
up and down. Use these arrows to
highlight the feature you wish to
adjust, as well as selecting the
desired adjustment value.
LCD screen
Provides visual feedback of the
functions and settings of the
3000TA controller.
Info Icon
Press this button at any time to display
information about the highlighted item
or adjustable feature. To exit the
information screen, press the Enter/
Exit button.
Enter/Exit Button
Use this button to enter an adjustment
feature (i.e. Sense Time, Run-On Time)
found in the main menu, as well as to
make the desired adjustments to that
feature. To exit, press the Enter/Exit
button again.
Making Adjustments - Controller Interface
►
►
▲
◄
◄
Fig. 11
w w w . s p e c s e l e c t . c o m
INSTALLATION AND SET UP INSTRUCTIONS
FOR RECESS MOUNT HOUSING: CONTROL BOXES #1 & 8