STEP 1. FAUCET INSTALLATION
Connect 20” braided hose to spout inlet. Clean deck/sink surface where faucet will be mounted.
Mount faucet to sink using nut(s) and washer(s) provided. Installation of the single hole deck
gasket (060564A) between the turret base and mounting surface is the recommended assembly
practice. Ensure that gasket is sitting flat on the deck and the turret is centered on the gasket.
Use the same procedure for installation of optional 4” or 8” deck plate package (060546A or
060547A). Mount the faucet to the sink using nut(s) and washer(s) provided. Do not overtighten
the nut (RP6087) or reposition the turret once installed, otherwise damage to the gasket may
result. Cutting or trimming of the gasket is not recommended.
NOTE: If the gasket is trimmed
or not installed, then use clear silicone sealant between the faucet and lavatory to prevent
water from leaking beneath lavatory.
STEP 2. BATTERY BOX INSTALLATION
Mount battery box to wall under sink using the 4 supplied screws and anchors. Use a 1/4” drill for
wall anchors.
Be sure to install the box within the dimensions provided so the hose and
spout cable will reach connections at faucet and battery box.
Refer to illustration (Fig. 2).
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 3) and run water for 1 minute.
Shut off water supply. Attach aerator.
NOTE:
Do not connect supply to the solenoid inlet until
line is flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 4) supply line and adaptor
to the bottom fitting on box, braided hose to the top fitting on box. Use plumber tape where
indicated on adaptor. Turn on water supply.
DO NOT SOLDER CONNECTIONS!
STEP 5. POWER UP
Unscrew the battery box lid screws (2). Install four Alkaline “C” batteries in holder or snap the
battery clip directly to the optional 24 VAC converter.
BATTERY VERSION
Use caution not to damage wires or components on electronic controller.
Install four Alkaline “C” batteries provided into the battery holder. After the batteries are installed,
make the sensor connection on the controller neatly inside the battery box. Connect battery clip
to battery pack. The blue backlit LCD screen will power up and the battery strength screen will
appear. See Fig 5
.
Ensure a drip loop is added to the sensor wire. Refer to Fig. 2. Secure lid
using screws.
HARDWIRE VERSION
Install CSA and/or UL approved Class 2 transformer or equivalent in a
convenient location.
(Do NOT install the transformer inside the control box.)
With the power
off, bring the 24 VAC supply wires to the box. Connect the 24 VAC supply to the 060683A
conversion kit. Connect the battery snap of the hardwire converter to the controller battery clip.
Ensure snap does not touch any conductive metal surface. Do not remove battery snap from
hardwire converter by using a flat screwdriver, damage may result. Turn on power supply for the
transformer and then make the sensor connection on the control module neatly inside the battery
box. Ensure a drip loop is added to the sensor wire. Refer to Fig. 2.
STEP 6. PREPARE SINK AREA
Before connecting the spout cable – clean off counter and remove all objects from the sink.
STEP 7. TIE SPOUT CABLE
Attach spout cable to box connector. Use tie wraps to secure spout cable to spout hose. Your
faucet is now ready for use (Fig. 2).
STEP 8. TEST FOR OPERATION
Test for operation.
If faucet leaks from spout outlet:
SHUT OFF WATER SUPPLIES. Replace solenoid (2).
If faucet exhibits very low flow:
A) Remove and clean spray outlet, or B) SHUT OFF WATER SUPPLY. Clean or replace screen
assembly (2).
If unit does not work properly, see Trouble Shooting Guide on page 7.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
7" (178 mm)
Max.
13" (331 mm) Max.
Tie Wraps
NOTE:
Entire connection can be placed
inside battery box if desired.
3/8" O.D.
Copper
Inlet
Bypass
Adapter
Ferrule
Nut
Spout
Hose
Plumber
Tape
Fig. 2
Fig. 3
Fig. 4
Trap
jacket of
cable in
hole for
strain
relief.
NOTE:
Always make
sure controller is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic controller.
2
1
Fig. 5
063131A
3/8” Comp
Connect Nut
and Ferrile
w w w . s p e c s e l e c t . c o m
Drip Loop