be damaged, it should be replaced by the exclusive cable.
☆
All electric installation must be done by professional personnel according to local law,
regulation and this manual.
☆
It should be reliably earthed, and it should be connected to the special earth device, the installation
work should be operated by the professional.
☆
The creepage protect switch and air switch must be installed.
Air switch should have the thermal dropout and magnetic dropout function, in order to avoid the
short circuit and overload.
☆
The on spot connection should refer to the circuit diagram, which is stuck on the unit body.
The model selection recommend table for air switch and power cable
Model Power
supply
Capacity
of air
switch(A)
Outdoor
power
supply
cord
(mm
2
)
Indoor
power
supply
cord
(mm
2
)
21CK018C24
220V~ 20
3
×
2.5
H07RN-F
3
×
4.0
H07RN-F
21CK024C24
220V~ 25
3
×
2.5
H07RN-F
3
×
4.0
H07RN-F
21CK036C24
220V~ 32
3
×
6.0
H07RN-F
3
×
1.0
H07RN-F
21CK048C24
220V~ 40
3
×
10.0
H07RN-F
3
×
1.0
H07RN-F
21CK060C24
220V~ 50
3
×
16.0
H07RN-F
3
×
1.0
H07RN-F
1、
The power cable used in the unit is copper cable, the working temperature should not exceed the specified value.
2、
If the power cable is longer than 15 meters, please enlarge the cross section of power cable adequately, in order to
avoid the accident due to overload.
Summary of Contents for 21CK018C24
Page 3: ...2 1 Names and functions of parts ...
Page 31: ...30 8 Optimum operation ...
Page 33: ...32 The following are not troubles ...
Page 34: ...33 10 Installation notes ...
Page 35: ...34 11 Care and maintenance Please pull out the power plug after you used the air conditioner ...
Page 36: ...35 ...
Page 37: ...36 ...
Page 38: ...37 The operation in detach and fix the flap is not including the 18K type ...
Page 49: ...48 Fig 8 butted terminals Fig 9 ...
Page 63: ......