Page 1

 

209489   Rev. C

PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as

items relating to ongoing maintenance suggestions and procedures are included.

060637A

1.5 GPM (5.7 L/min)

VR Laminar Outlet with

Antimicrobial by Agion

®

060639A

1.5 GPM (5.7 L/min)

VR Flow Control Aerator

& Wrench

060564A

Single Hole Deck

Gasket (6/pkg)

RP6087

Nut & Washer

Note:

 See page 3 for parts breakdown

on recessed mount boxes.

063254A

Deck Plate Nut & Washers

060546A

4” Deck Plate & Hold-Down Package

060547A

8” Deck Plate & Hold-Down Package

060564A

Single Hole Deck Gasket (6/pkg)

209489        209489        209489        209489

         

 

         

 

         

 

         

 

209489        209489        209489        209489

        

 

         

 

         

 

         

 

NOTE:

 Control Box #0 and #1 are designed for routine 171°F (77°C)

disinfection cycles up to 30 minutes.

Control Box #8 is not recommended for high temperature disinfection

cycles as the thermostatic mixing valve limits the higher temperature

flow output.

NOTE:

 For optimum performance of this product, we recommend a

system pressure between 20 and 80 PSI static.  This product will

operate up to a maximum of 125 PSI static per ANSI and CSA

requirements.  However, we do not recommend pressure above 80

PSI.  Thermal expansion or leaking pressure reducing valves may

require use of expansion tanks or relief valves to ensure your system

never exceeds its maximum intended pressure setting.

061256A

36” Cable

Extension

RP30523

Braided Hose

060683A

24VAC to 6VDC

Converter

063245A

2.2 GPM

(8.3 L/min)

063139A

0.5 GPM

(1.9 L/min)

063140A

1.5 GPM

(5.7 L/min)

Adapter with

Flow Control

for smooth

end spouts

063193A (R5)

063194A (R7)

063195A (R35)

Single-Hole Mount

Assembly including

Sensor and Hold-Down

Package and Spout

with aerator thread

w w w . s p e c s e l e c t . c o m

Write purchase model number here for future reference

150__T3__ __ __

Outlet #1

2.2 GPM (8.3 L/min)

063236A (R5)

063237A (R7)

063238A (R35)

Outlet #7

1.5 GPM (5.7 L/min)

063183A (R5)

063184A (R7)

063185A (R35)

Outlet #8

0.5 GPM (1.9 L/min)

063188A (R5)

063189A (R7)

063190A (R35)

OPTION LIST

 

TRANSFORMERS

060704A

Transformer 110 to 24 VAC 20VA

up to 5 Electronic Valves

060771A

Transformer 110 to 24 VAC 40VA

up to 10 Electronic Valves

DECK PLATES

060546A

4” Deck Plate & Hold-Down Pkg

060547A

8” Deck Plate & Hold-Down Pkg

060681A

Battery Holder

*Package Quantities May Change.

Check the Parts section of the latest Delta Commercial Faucet Price List for current quantities.

   

 

063128A

Battery Box Assembly less driver

board and battery holder

063131A

3/8” Comp Connect Nut

and Ferrile

060909A

Screen Assembly

060908A

Solenoid Holder

063127A

Solenoid Valve with 3/8”

Compression Connectors

061252A

Dual Driver

Board Masco

H2Optics

& Proximity

060906A

Surface

Mount Housing

060905A

Cover Gasket

OR

Fig. 1

Single-Hole Mount 

Assembly including

 Sensor and Hold-Down

Package and Spout

(with smooth ends)

Summary of Contents for 150 T3 Series

Page 1: ...aximum intended pressure setting 061256A 36 Cable Extension RP30523 Braided Hose 060683A 24VAC to 6VDC Converter 063245A 2 2 GPM 8 3 L min 063139A 0 5 GPM 1 9 L min 063140A 1 5 GPM 5 7 L min Adapter w...

Page 2: ...re converter by using a flat screwdriver damage may result Turn on power supply for the transformer STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects...

Page 3: ...Depending on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Figure 8 The transformer is to be installed in an adjacent accessible space...

Page 4: ...w in the direction of water flow See Fig 10 Feed sensor wire from spout into control box and then connect to the driver board Connect red solenoid wire from the driver board to marked solenoid termina...

Page 5: ...le If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the...

Page 6: ...changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected and will continue to run after the user removes their hands Options are OF...

Page 7: ...r 060683A if required The faucet stops working No water flow Check the function of the solenoid Step 3 The solenoid should click when activated Clean as required Correct as required If there is a clic...

Page 8: ...you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta F...