Hardware Reference Manual
E-Point Jumper Descriptions
40
E5: Servo Gate Address Select
E Point and
Physical Layout
Location Description
Default
E5
E5
Jump pin 1 to 2 to address Acc-1P channels at the
regular addresses for channels 5 to 8.
Jump pin 2 to 3 to address Acc-1P channels at the
regular addresses for channels 5 to 8 plus $40.
1-2 Jumper installed
E6: I/O Gate Address Select
E Point and
Physical Layout
Location Description
Default
E6
E5
Jump pin 1 to 2 to address Acc-1P I/O ports at
the regular addresses.
Jump pin 2 to 3 to address Acc-1P I/O ports at
the regular addresses plus $40.
1-2 Jumper installed
E7: Machine Input Source/Sink Control
E Point and
Physical Layout
Location Description
Default
E7
E5
Jump pin 1 to 2 to apply +5V to input reference
resistor sip pack; this will bias MI1 to MI8 inputs
to +5V for OFF state; input must then be
grounded for ON state.
Jump pin 2 to 3 to apply GND to input reference
resistor sip pack; this will bias MI1 to MI8 inputs
to GND for OFF state; input must then be pulled
up for ON state (+5V to +24V).
1-2 Jumper installed
E16: ADC Inputs Enable
E Point and
Physical Layout
Location Description
Default
E16
D1
Jump pin 1 to 2 to enable the Option-12 ADC
inputs.
Remove jumper to disable the ADC inputs,
which might be necessary for reading current
feedback signals from digital amplifiers.
No jumper
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com