ACC-72EX User Manual
Hardware
19
Communication Option-Dependent E-Point Jumper Settings
Comm. Protocol Option
Option Part Number
E8
E10
E11
E12
PROFIBUS-DP – Master
310-603958-OPT
1-2
OFF
OFF
OFF
PROFIBUS-DP – Slave
311-603958-OPT
1-2
OFF
OFF
OFF
DeviceNet – Master
320-603958-OPT
2-3
ON
OFF
OFF
DeviceNet – Slave
321-603958-OPT
2-3
ON
OFF
OFF
CANopen – Master
330-603958-OPT
OFF
OFF
ON
OFF
CANopen – Slave
331-603958-OPT
OFF
OFF
ON
OFF
CC-Link – Slave
351-603958-OPT
2-3
OFF
OFF
ON
EtherCAT – Master
360-603958-OPT
OFF
OFF
OFF
OFF
EtherCAT – Slave
361-603958-OPT
OFF
OFF
OFF
OFF
EtherNet/IP – Scanner/Master
370-603958-OPT
OFF
OFF
OFF
OFF
EtherNet/IP – Adaptor/Slave
371-603958-OPT
OFF
OFF
OFF
OFF
Open Modbus/TCP
380-603958-OPT
OFF
OFF
OFF
OFF
PROFINET IO – Controller
390-603958-OPT
OFF
OFF
OFF
OFF
PROFINET IO – Device
391-603958-OPT
OFF
OFF
OFF
OFF
NOTES:
E8: Determines the signal on pin 5 of the Fieldbus 9-pin D-Sub Connector. The position of the jumper depends
on the COMX module installed/option ordered.
E10: Adds 120
Ω
termination resistor for DeviceNet communication lines
E11: Adds 120
Ω
termination resistor for CANopen communication lines
E12: Adds 110
Ω
termination resistor for CC-Link communication lines