Accessory 24E2S
E-Point Jumper Settings
6
E-POINT JUMPER SETTINGS
Acc-24E2S Jumpers*
Jumper Config. Description
Default
E1
1-2-3
1-2 send PWM/PFM output regardless of AENA1 status
2-3 send PWM/PFM only when AENA1 if true.
No Jumper for Channel 1 TUVW inputs.
Jump 1-2
E2
1-2-3
1-2 send PWM/PFM output regardless of AENA2 status
2-3 send PWM/PFM only when AENA2 if true.
No Jumper for Channel 2 TUVW inputs.
Jump 1-2
E3
1-2-3
1-2 send PWM/PFM output regardless of AENA3 status
2-3 send PWM/PFM only when AENA3 if true.
No Jumper for Channel 3 TUVW inputs.
Jump 1-2
E4
1-2-3
1-2 send PWM/PFM output regardless of AENA4 status
2-3 send PWM/PFM only when AENA4 if true.
No Jumper for Channel 4 TUVW inputs.
Jump 1-2
E5
1-2-3
Jump 1-2 for Turbo 3U CPU and MACRO CPU
** Jump 2-3 for legacy MACRO CPU (before 6/00)
Jump 1-2
E11
1-2
Jump 1-2 to enable AENA1
No Jumper to disable AENA1
Jump 1-2
E12
1-2
Jump 1-2 to enable AENA2
No Jumper to disable AENA2
Jump 1-2
E13
1-2
Jump 1-2 to enable AENA3
No Jumper to disable AENA3
Jump 1-2
E14
1-2
Jump 1-2 to enable AENA4
No Jumper to disable AENA4
Jump 1-2
E16
1-2-3
Jump 1-2 to receive phase and servo clocks
Jump 2-3 to transmit phase and servo clocks
Factory set
OPT1
1-2
For factory use only (No jumper on JP1-JP9)
Factory set
OPT2
1-2
For factory use only (Jumper JP1-JP9)
Factory set
OPT3
1-2
For factory use only (jumper JP1-JP9)
Factory set
*The channels refer to the Servo IC associated with the individual Acc-24E2S board. For example, in
an eight-axis application, there would be two Acc-24E2S boards. The first Acc-24E2S would have
axes 1-4 and the second Acc-24E2S would contain axes 5-8.
** For legacy MACRO Stations (part number 602804-100 through 602804-104)
Note:
Delta Tau added the amplifier enable outputs with the release of the 603441-101
revision of the Acc-24E2S card and jumpers E11, E12, E13, and E14 were added
for this feature. The first revision of this accessory (603441-100) does not have
amplifier enable outputs or jumpers E11, E12, E13, or E14.