Accessory 24E2S
MLDT Feedback for UMAC-Turbo & UMAC-MACRO
28
Line 1 (Method and Address):
This 24-bit value (6 hex digits) should begin with a 3 (filtered parallel
data) followed by the address of the timer register. The possible values for this line are shown in the
following table:
Encoder Conversion Table Parallel Filtered Data Format First Line for Acc-24E2S Boards with
Servo IC m Channel n
Acc-24 #
Servo IC #
Channel 1
Channel 2
Channel 3
Channel 4
1A
2
$378200
$378208
$378210
$378218
1B
3
$378300
$378308
$378310
$378318
2A
4
$379200
$379208
$379210
$379218
2B
5
$379300
$379308
$379310
$379318
3A
6
$37A200
$37A208
$37A210
$37A218
3B
7
$37A300
$37A308
$37A310
$37A318
4A
8
$37B200
$37B208
$37B210
$37B218
4B
9
$37B300
$37B308
$37B310
$37B318
Line 2 (Width and Start):
This 24-bit value should be set to $013000 to specify the use of 19 bits
($013) starting at bit 0.
Line 3 (Max Change):
This 24-bit value should be set to a value slightly greater than the maximum true
velocity ever expected, expressed in timer LSBs per servo cycle. With a typical MLDT, the 117.96 MHz
timer LSB represents 0.024 mm (0.00094 inches); the default servo cycle is 0.442 msec.
The result of this conversion is in the X-register of the third line. Any functions using this value should
address this register. For example, if this were the first entry in the table, which starts at $003501, the
result would be in X:$003503.
Motor I-Variables
Ixx03 (Position Loop Feedback Address)
To use the result of the conversion table for position-loop feedback for Motor xx, Ixx03 should contain
the address of the result register in the conversion table - $003503 in the above example.
Ixx04 (Velocity Loop Feedback Address)
To use the result of the conversion table for velocity-loop feedback for Motor xx, Ixx04 should contain
the address of the result register in the conversion table - $003503 in the above example.
Ixx05 (Master Position Address)
To use the result of the conversion table for the master position for Motor xx, Ixx05 should contain the
address of the result register in the conversion table - $003503 in the above example.
Ixx10 and Ixx95 (Power-On Position Address and Format)
To use the MLDT for absolute power-on position for Motor xx, Ixx95 should be set to $180000 (up to 24
bits of parallel Y-data) and Ixx10 should be set to the address of the timer register used:
Ixx10 for Acc-24E2A MLDT Timer Registers (Ixx95=$180000)
Acc-24 #
Servo IC #
Channel 1
Channel 2
Channel 3
Channel 4
1A
2
$078200
$078208
$078210
$078218
1B
3
$078300
$078308
$078310
$078318
2A
4
$079200
$079208
$079210
$079218
2B
5
$079300
$079308
$079310
$079318
3A
6
$07A200
$07A208
$07A210
$07A218
3B
7
$07A300
$07A308
$07A310
$07A318
4A
8
$07B200
$07B208
$07B210
$07B218
4B
9
$07B300
$07B308
$07B310