10
⚫
Use with a WET150 Meter
Use with a WET150 Meter
Use it to take readings or change the address.
Settings for soil type, conductivity units and
temperature units can also be changed.
Take a Reading
1. Gently insert WET150 pins into soil or
substrate.
2. Press READ to take and display water
content, temperature and pore water
conductivity.
Options
Water content
can be displayed as volumetric water
content (%) using the
Mineral, Peat mix, Coir, Min. wool
and
Perlite
calibrations or the meter can display the
RAW
(unconverted) permittivity
reading (ε’) which has no units.
Temperature
can be displayed in °C or °F.
EC
is displayed as the pore water conductivity, EC
p
, in mS.m
-1
, or the soil
bulk conductivity, EC
b
, when the
RAW
display option is selected.
Address
can be
a
to
z
,
A
to
Z
or
0
to
9
( 0 is not advised on a network)
WET150 Meter Buttons
READ
– takes and displays a reading.
SET
shows the settings menu. You can scroll up or down
through these options: Soil type, Units and Address and
Contrast... Press SET to select the highlighted menu and show
the current setting in that menu. Again, scroll up or down and
press SET to confirm the choice and return to the start-up
screen. Alternatively, press READ to save the setting, exit the
menu and take a reading.
and scroll through the current options.
Auto-off - after 1 minute saves the current selection and
switches off.
See also
WET150 Kit Quick Start
Guide