HD35
- 133 -
V1.12
THERMOCOUPLE TEMPERATURE PROBES
TP35K6.5
Stainless steel temperature probe. K-type thermocouple sensor wih isolated
junction. Cable length 5 m.
Cable ending with
f
ree wires.
P
ROBES FOR
WBGT
MEASUREMENT
TP3501TC2
Natural ventilation wet bulb probe. Pt100 sensor. Probe stem probe: Ø 14 mm,
length 110 mm. 2 m cable with 4-pole M12 connector. Complete with two spare
cotton wicks and 50 cc distilled water container.
TP3204
Natural ventilation wet bulb probe for long-lasting measurements. Capacity:
500 cc of distilled water. Pt100 sensor. 2 m cable with 4-pole M12 connector.
Complete with 500 cc bottle and two spare cotton wicks.
TP3575TC2
Pt100 sensor globe-thermometer temperature probe, globe Ø 150 mm. Stem:
Ø 14 mm, length 110 mm. 2 m cable with 4-pole M12 connector.
TP3576TC2
Pt100 sensor globe-thermometer temperature probe, globe Ø 50 mm. Stem:
Ø 8 mm, length 170 mm. 2 m cable with 4-pole M12 connector.
TP3507TC2
Temperature probe. Pt100 1/3 DIN sensor. Probe stem: Ø 14 mm, length 140
mm. 2 m cable with 4-pole M12 connector.
HD32.2.7.1
Holder for probes, to be fixed on the tripod.
VTRAP30
Tripod, maximum height 280 mm.
HD9007A-3
6-ring protection from solar radiations for the HP3517ETC2… probe.
HD9007T26.2 Fitting for Ø 14 mm probes for the HD9007A-3 protection from solar radiations.
HD32.4.17
Bracket for fixing the WBGT measurement system to a wall or a mast.
HD2013.2.14 3-sector clamping for mast
∅
40 mm with 6 inputs
∅
16 mm.
HD3218K
Clamp shaft for fixing a probe to the HD2013.2.14 flange.
P
HOTOMETRIC
–
RADIOMETRIC PROBES
LP 35 PHOT
Photometric probe for measuring illuminance, CIE photopic filter, spectral re-
sponse according to the standard photopic curve, diffuser for cosine correc-
tion. Measuring range: 0.1…200,000 lux. Cable length 5 m.
LP 35 PHOT03BL Photometric probe for measuring illuminance, CIE photopic filter, spectral re-
sponse according to the standard photopic curve, diffuser for cosine correction,
K5 dome. Measuring range: 0.1…200,000 lux. The cable (CPM12 AA5…D)
has to be ordered separately.
LP 35 P-A
Combined probe with two sensors for measuring illuminance, with standard
photopic spectral response, and irradiance in the UVA spectral range
315 nm…400 nm, diffuser for cosine correction. Illuminance measuring range:
0.3…20.000 lux. Irradiance measuring range: 1…10.000 mW/m
2
. Cable length
5 m.
LP 35 UVA
Radiometric probe for measuring irradiance in the UVA spectral range 315 nm
…400 nm, diffuser for cosine correction. Measuring range: 1…10.000 mW/m
2
.
Cable length 5 m.
LP 35 UVB
Radiometric probe for measuring irradiance in the UVB spectral range 280 nm
…315 nm, diffuser for cosine correction. Measuring range: 1
⋅
10
-3
…100 W/m
2
. Ca-
ble length 5 m.
LP 35 UVC
Radiometric probe for measuring irradiance in the UVC spectral range 220 nm
…280 nm, diffuser for cosine correction. Measuring range: 1
⋅
10
-3
…100 W/m
2
. Ca-
ble length 5 m.