background image

10

4/  Troubleshooting

You wish to set the stops again. 

 

You must first erase the existing stops.

Tymoov FE

Press button B, then set button A to position I or II. 

 

After 5 seeconds, the motor briefly activates once. 

 

The stops have now been deleted.

Tymoov F2

- Lower the shutter completely,

- Set button A to STOP within 5 seconds of the shutter stopping,

- Then, perform the following sequence of presses: v - Stop - v - Stop (<3 seconds between each press), 

 

then press and hold v. 

 

The motor briefly activates twice. The 2 stops are erased. 

 

OR

- Set the shutter to the top position,

- Set button A to STOP within 5 seconds of the shutter stopping,

- Then, perform the following sequence of presses: ^ -Stop-^-Stop (<3 seconds between each press), then 

press and hold ^. 

 

The motor briefly activates twice. The 2 stops are erased.

Tymoov RE2/RP2

Button A at position I, 

 

press briefly on button B to move the motor towards its top or bottom stop. 

 

In the 5 seconds following the stopping of the shutter, set button A to STOP and wait for 10 seconds. 

Then, while holding button B pressed down, toggle button A to I and only release button B when the motor 

activates twice.

The stops are now erased.

• Operating voltage: 230 V / 50 Hz 

• Max. power : 6 (4) A / 250 V AC

• Operating temperature: 0 à 40 °C

• Storage temperature: -10°C to +60 °C / Max. air humidity 90 %

• Protection rating: II

• Cable length: 2.88 m

5/  Technical specifications

www.deltadore.com

11/22