10
4/ Troubleshooting
You wish to set the stops again.
You must first erase the existing stops.
Tymoov FE
Press button B, then set button A to position I or II.
After 5 seeconds, the motor briefly activates once.
The stops have now been deleted.
Tymoov F2
- Lower the shutter completely,
- Set button A to STOP within 5 seconds of the shutter stopping,
- Then, perform the following sequence of presses: v - Stop - v - Stop (<3 seconds between each press),
then press and hold v.
The motor briefly activates twice. The 2 stops are erased.
OR
- Set the shutter to the top position,
- Set button A to STOP within 5 seconds of the shutter stopping,
- Then, perform the following sequence of presses: ^ -Stop-^-Stop (<3 seconds between each press), then
press and hold ^.
The motor briefly activates twice. The 2 stops are erased.
Tymoov RE2/RP2
Button A at position I,
press briefly on button B to move the motor towards its top or bottom stop.
In the 5 seconds following the stopping of the shutter, set button A to STOP and wait for 10 seconds.
Then, while holding button B pressed down, toggle button A to I and only release button B when the motor
activates twice.
The stops are now erased.
• Operating voltage: 230 V / 50 Hz
• Max. power : 6 (4) A / 250 V AC
• Operating temperature: 0 à 40 °C
• Storage temperature: -10°C to +60 °C / Max. air humidity 90 %
• Protection rating: II
• Cable length: 2.88 m
5/ Technical specifications
www.deltadore.com
11/22