background image

8

9

EN

Tymoov RE2/RP2

 Only connect the motor cables to the console 

without a control point or intermediary

 Supply power to the console by connecting the 

plug to the mains outlet

When switched on for the first time, with button A in position I:

 

 the motor will a quick cycle to warn that no transmitter is paired. 

 

The motor is automatically set to pending pairing for 5 minutes.

 Setting stops

Automatic

1st stop: 

Button A at position I, press button B for 2 seconds to activate the motor. When the motor has 

detected its 1st stop (top or bottom), it activates once.

2nd stop: 

press button B for 2 seconds to activate the motor. When the motor has detected its 2nd stop, it 

activates twice.

 

The stops are memorised.

Semi-automatic

1st stop in automatic mode: 

Button A at position I, press button B for 2 seconds so that the motor activates (if the direction of rotation 

does not correspond to the stop that you wish to set, briefly press button B, then press button B once again 

for 2 seconds so that the motor activates again, in the opposite direction). Once the stop has been reached, 

the motor will activate once.

2nd stop in manual mode:  

Button A always in position I, press button B for 2 seconds to activate the motor. 

 

Briefly press button B to stop at the desired position. 

 

For the top stop, perform 2 short presses on button B, then a long press (longer than 2 seconds). 

 

For the bottom stop, perform 3 short presses on button B, then a long press (longer than 2 seconds).

The motor activates twice to confirm that the 2nd stop has been memorised.

Manual

Button A to position I. 

 

Press button B for 2 seconds until the motor activates. 

 

To stop the motor, briefly press button B.

For the bottom stop, perform 3 short presses and a long press (>2 seconds) on button B. 

 

For the top stop, perform 2 short presses and a long press (>2 seconds) on button B.

 

The motor activates once when the 1st stop has been stored.

To set the 2nd stop: repeat the procedure from the start. 

 

The motor will activate twice to confirm that the 2nd stop has been saved.

 Disconnect the console

- Remove the plug from the mains outlet

- Disconnect the motor connection cord

- Reconnect the tubular motor to the mains supply (see instructions).

Brown

Blue

Grey

Yellow / Green

Black

Black

Brown

3/ Connection / Setting of the stops