❶
Only connect the motor cables to the console
without a control point or intermediary
❷
Supply power to the console by connecting the
plug to the mains outlet
When switched on for the first time, with button A in position I:
the motor will a quick cycle to warn that no transmitter is paired.
The motor is automatically set to pending pairing for 5 minutes.
❸
Setting stops
Automatic
1st stop:
Button A at position I, press button B for 2 seconds to activate the motor. When the motor has
detected its 1st stop (top or bottom), it activates once.
2nd stop:
press button B for 2 seconds to activate the motor. When the motor has detected its 2nd stop, it
activates twice.
The stops are memorised.
Semi-automatic
1st stop in automatic mode:
Button A at position I, press button B for 2 seconds so that the motor activates (if the direction of rotation
does not correspond to the stop that you wish to set, briefly press button B, then press button B once again
for 2 seconds so that the motor activates again, in the opposite direction). Once the stop has been reached,
the motor will activate once.
2nd stop in manual mode:
Button A always in position I, press button B for 2 seconds to activate the motor.
Briefly press button B to stop at the desired position.
For the top stop, perform 2 short presses on button B, then a long press (longer than 2 seconds).
For the bottom stop, perform 3 short presses on button B, then a long press (longer than 2 seconds).
The motor activates twice to confirm that the 2nd stop has been memorised.
Manual
Button A to position I.
Press button B for 2 seconds until the motor activates.
To stop the motor, briefly press button B.
For the bottom stop, perform 3 short presses and a long press (>2 seconds) on button B.
For the top stop, perform 2 short presses and a long press (>2 seconds) on button B.
The motor activates once when the 1st stop has been stored.
To set the 2nd stop: repeat the procedure from the start.
The motor will activate twice to confirm that the 2nd stop has been saved.
❹
Disconnect the console
- Remove the plug from the mains outlet
- Disconnect the motor connection cord
- Reconnect the tubular motor to the mains supply (see instructions).
Brown
Blue
Grey
Yellow / Green
Black
Black
Brown
3/ Connection / Setting of the stops