5

Recommendations

- Correct operation of the motor is ensured if it is installed and used 

according to the following recommendations.  
The peripheral elements such as the roller tube, supports, fastenings, 
etc. must be chosen correctly and assembled in compliance with 
good practice. Furthermore, the motor operating environment and 
power required are elements that must be carefully chosen and 
assessed. The characteristics of the driven part must be compatible 
with the rated load and operating time.

- A-weighted sound pressure level: LpA ≤ 70 dB(A).

- Cables going through a metal wall must be protected and isolated by 

a sleeve. 
The TYMOOV xRP2/DxRP2 or xRE2 cable can be disassembled.

- If the power cable is damaged, it must be replaced by the 

manufacturer, after-sales service or similarly qualified personnel in 

order to prevent hazards.

- The motor must be chosen according to the requirements of the load 

bearing support. See our charts for selecting the motor according to 
the shutter type. A plate on the motor indicates the nominal torque 
and operating time.

- TYMOOV xRP2/DxRP2 or xRE2 tubular motors are designed to 

operate intermittently (4 minutes of continuous operation). They 
are electronically protected to prevent overheating. If there is a 
thermal shutdown, the motor will operate again after a time period 

of approximately 30 seconds. To operate again for 4 minutes, the  

motor must have returned to room temperature.

- If an attempt is made to raise the shutter (for example: intruder test), 

the motor will lower the apron. Caution, your fingers may be caught.

DELTA DORE hereby declares that the motorised systems covered by these 

instructions comply with the essential requirements set out by the Machinery 

Directive 2006/42/EC and the European directive RED 2014/53/EU.

The EU declaration for this equipment is available on request

 

from:

Service “Info techniques”

DELTA DORE – 35270 Bonnemain (France)

email: [email protected]

DELTA DORE

35270 - BONNEMAIN - France

[email protected]

Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this 

document are not binding unless confirmed by our departments.

Summary of Contents for TYMOOV 10RE2

Page 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP2 DxRP2 xRE2 ...

Page 2: ...nd that the risks involved have been understood Children must not play with the device Cleaning and maintenance by the user must not be carried out by unsupervised children The operating device of an unlockable switch must be in direct view of the driven part but kept away from the moving parts It must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visi...

Page 3: ...type A plate on the motor indicates the nominal torque and operating time TYMOOV xRP2 DxRP2 or xRE2 tubular motors are designed to operate intermittently 4 minutes of continuous operation They are electronically protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must h...

Page 4: ...g the first remote control to a motor 11 4 2 Setting stops 12 5 Modifying stops 16 6 Associating another transmitter 16 7 Linking a smoke detector directly to the motor 17 8 Grouped command 17 9 Obstacle detection 18 9 1 Setting of the obstacle detection type 18 9 2 Adjustment of the sensitivity of obstacle detection for Basic detection only 19 10 Remove one or several associations 19 10 1 Remove ...

Page 5: ...ling L Total length TYMOOV 6 10 and 20 Nm 395 mm 424 mm Tube L length for drilling wheel attachment by screws or rivet 2 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 2 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 NO 8 NO 8 NO 4 OK 4 OK 4 OK C...

Page 6: ...associate The corresponding shutter will be activated briefly once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit association mode hold for 3 seconds You will then be able to pass to Set stops mode 3s The electrical wiring must comply with EN IEC and national institute standards for installation e g NF ...

Page 7: ...n slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated briefly The stop position will now be automatically set The motor will be activated twice Automatic upper stop Automatic lower stop The stop...

Page 8: ...lease the and buttons at the same time To scroll step by step briefly press then release the and buttons at the same time Press button B on the front panel of the remote control until the LED flashes green Then press and hold the button for 3 seconds until the motor is activated briefly The upper manual stop will now be set The motor will be activated briefly Press the button to move the shutter t...

Page 9: ...he opening of roller shutters in the event that smoke is detected Motor type Linking to a wireless smoke detector TYMOOV xRP2 and DxRP2 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Wireless smoke detector directly linked to the motor TYMOOV xRE2 Version S02 04 00 Only by linking your motor and the wireless smoke detector to a TYXAL alarm system To find out the...

Page 10: ... DxRP2 motors you have a choice between two detection modes Protect Detection default mode more efficient obstacle detection preventing the apron from unwinding in the casing Basic Detection detection of obstacles with unwinding of the apron in the casing Repeat the operations above to switch between modes The Radio Efficacité xRE2 motor only has Basic obstacle detection 3s x 2 Press button B on t...

Page 11: ...unit to Maintenance mode then to Add product mode Set the alarm control unit to Add product mode Associate the intruder mode with the alarm control unit Press button B on the front panel of the remote control twice until the LED flashes orange Then press and hold the button for 3 seconds until the motor is activated briefly The alarm control unit will beep The alarm control unit will beep The roll...

Page 12: ...t the motor is in association wait mode it only remains in association mode for 2 minutes 12 2 Associating an Efficacité RE2 radio motor 12 3 Defining the motor s operating mode 5s Bip ON OFF 3s x 1 x 2 On the motor remote control press the button for more than 3 seconds until the motor operates briefly Set the alarm control unit to Maintenance mode open it and then briefly press button 2 of the c...

Page 13: ... stop then a manual stop Press the push button 2 seconds so that the motor operates in the up or down direction When the motor detects the 1st stop upper or lower then the motor operates once 2s x 1 OR x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the opposite direction Briefly press the push button to stop the motor at the position corresponding to the...

Page 14: ...2 manual stops x 3 2s 2s x 2 2s x 2 STOP OR Press the push button 2 seconds so that the motor operates in the up or down direction Briefly press the push button to stop the motor at the position corresponding to the manual stop Then if the shutter is down briefly press the push button 3 times then press and hold the push button 2 seconds if the shutter is up briefly press the push button 2 times t...

Page 15: ...n on the remote control 3 times The motor operates twice x 2 x 1 TYMOOV xRP2 and DxRP2 software version S02 04 00 and higher The motor operates once x 2 x 1 TYMOOV xRE2 software version S02 04 00 and higher The motor does not respond TYMOOV xRE2 or xRP2 or DxRP2 software version S02 04 00 See label on the motor 17 Troubleshooting Press the push button once to move the shutter down or up Switch off...

Page 16: ...www deltadore com 05 21 ...